DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5930-01-314-9568 to receive an up to date pricing and availability quote by email.

5930-01-314-9568
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5930 Switches
National Stock Number
5930-01-314-9568
Item Name Code
02134
Assigment Date
02/09/1990 (36 years ago)

A switch actuated by a definite angular rotation of the switch shaft about its axis. It consists of a body,switch and a control,rotary switch. For items having rated actuation travel and pressure characteristics, see switch,sensitive. Excludes relay,rotary; switch,stepping; and switch,telephone (as modified).

0.437 inches nominal single mounting facility thread length, 2a single mounting facility thread class, 3.057 inches nominal overall length, 0.250 inches nominal 2nd actuator first flat length, corrosion resistant hazardous locations/environmental protection

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Thread Class
2a single mounting facility
Thread Length
0.437 inches nominal single mounting facility
Hazardous Locations/Environmental Protection
corrosion resistant
Overall Length
3.057 inches nominal
First Flat Length
0.250 inches nominal 2nd actuator
First Flat Length
0.250 inches nominal 1st actuator
Flat Height
0.093 inches nominal 2nd actuator
Flat Height
0.216 inches nominal 1st actuator
Shaft Diameter
0.125 inches nominal 2nd actuator
Shaft Diameter
0.250 inches nominal 1st actuator
Shaft Length
0.375 inches nominal 1st actuator
Shaft Length
1.000 inches nominal 2nd actuator
Overall Diameter
1.000 inches nominal
Nonturn Device Radius
0.375 inches nominal at 3:00 o'clock
Individual Section Quantity
1
Nonturn Device Type
tab at 3:00 o'clock
Switch Contact Basic Design
nonpile-up symmetrical
Pole Quantity
2 single section front
Throw Quantity
2 single section rear
Mounting Method
threaded bushing single mounting facility
Features Provided
variable resistor provisions
Nominal Thread Size
0.375 inches single mounting facility
Contact Voltage Rating In Volts
115.0 ac at sea level
Contact Voltage Rating In Volts
30.0 dc at sea level
Rotor Through Connection Quantity
2 single section
Switch Actuator Indexing Position Quantity
2 1st actuator
Shaft Type
round, flatted 2nd actuator
Shaft Type
round, flatted w/through hole 1st actuator
Terminal Type
tab, solder lug
Contact Switching Action
breaks before makes single section rear
Switch Actuator Positioning Increment
60.0 degrees 1st actuator
Switch Actuator Stop Device Type
fixed stop 1st actuator
Contact Load Current Rating
3.0 amperes resistive load ac at sea level
Contact Load Current Rating
1.5 amperes resistive load dc at sea level
Precious Material And Location
contacts and rotor blade surfaces silver and contacts and rotor blade surfaces gold
Precious Material
silver and gold
Style Designator
tap, circular, bushing mount
Thread Series Designator
unef single mounting facility

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
1860F/1108 Rotary Switch
G376829 Rotary Switch

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5930-01-314-9568?
The FSCG of the NSN 5930-01-314-9568 is 5930
Does the NSN 5930-01-314-9568 have a Schedule B code assigned?
Yes, the Schedule B code is 8536509020
Does NSN 5930-01-314-9568 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5930-01-314-9568 contain precious materials?
Item contains silver.
Does NSN 5930-01-314-9568 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5930-01-314-9568 was assigned to the Federal Catalog?
It was assigned 36 years ago, on Fri, Feb 9, 1990

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

6515NCM051829
6515-01-537-1499
Micro-Handpiece
6515NCM051832
6515-01-454-9236
Surgical Stomach Tube
6515NCM051833
6515-01-454-9238
Surgical Stomach Tube
6515NCM051834
6515-01-372-8143
Surgical Stomach Tube
6515NCM051848
6515-01-536-8028
Handhel Spot Vital Signs Monitor
6515NCM051850
6515-01-538-0709
Audiometer
6515NCM051852
6515-01-537-4054
Electrocardiograph
6515NCM060026
6545-01-537-0686
Combat Casualty Care Tc3 Bag
6515NCM060027
6515-01-537-2397
Intraosseous Infusi Removal Tool
6515NCM060033
6515-01-530-8137
Vital Signs Monitor Cable
6515NCM060034
6515-01-519-6131
Defibrillation and Cpr Electrode
6515NCM060038
6515-01-538-0272
Temperature Monitoring Kit
6515NCM060039
6515-01-537-1534
Personal Protection Kit
6515NCM060040
6515-01-538-0276
Temperature Monitoring Kit
6515NCM060043
6515-01-537-1531
Respirator Mask