DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5930-01-170-5785 to receive an up to date pricing and availability quote by email.

5930-01-170-5785
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5930 Switches
National Stock Number
5930-01-170-5785
Item Name Code
02134
Assigment Date
01/27/1984 (42 years ago)

A switch which is externally actuated by a lever and whose contacts open and close with an instantaneous (snap) action; includes items having one or more momentary positions. Includes switches (snap action) which use mercury to bridge contacts, and assemblages of complete switches (snap action) having common actuators. Excludes:switch,lever; switch,rotary; switch,knife; switch,sensitive; and switch,box.

0.250 inches nominal single actuator first flat length, 0.375 inches nominal single mounting facility thread length, 1.858 inches nominal overall length, 0.218 inches nominal single actuator flat height, 2a single mounting facility thread class

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Thread Class
2a single mounting facility
Thread Length
0.375 inches nominal single mounting facility
Overall Length
1.858 inches nominal
First Flat Length
0.250 inches nominal single actuator
Flat Height
0.218 inches nominal single actuator
Shaft Diameter
0.250 inches nominal single actuator
Shaft Length
0.750 inches nominal single actuator
Overall Diameter
1.312 inches nominal
Nonturn Device Radius
0.531 inches nominal at 3:00 o'clock
Individual Section Quantity
2
Nonturn Device Type
pin at 3:00 o'clock
Switch Contact Basic Design
nonpile-up symmetrical
Pole Quantity
3 each section front
Throw Quantity
3 each section front
Mounting Method
threaded bushing single mounting facility
Nominal Thread Size
0.375 inches single mounting facility
Contact Voltage Rating In Volts
28.0 dc at sea level
Contact Voltage Rating In Volts
300.0 ac at sea level
Switch Actuator Indexing Position Quantity
3 single actuator
Shaft Type
round, flatted single actuator
Terminal Type
tab, solder lug
Contact Switching Action
breaks before makes each section front
Switch Actuator Positioning Increment
30.0 degrees single actuator
Switch Actuator Stop Device Type
fixed stop single actuator
Contact Load Current Rating
50.0 milliamperes resistive load ac at sea level
Contact Load Current Rating
500.0 milliamperes resistive load and 50.0 milliamperes inductive load dc at sea level
Style Designator
circular wafer, bushing mount
Thread Series Designator
unef single mounting facility

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
4871-09511 Rotary Switch
5-31262-761 Rotary Switch

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5930-01-170-5785?
The FSCG of the NSN 5930-01-170-5785 is 5930
Does the NSN 5930-01-170-5785 have a Schedule B code assigned?
Yes, the Schedule B code is 8536509020
Does NSN 5930-01-170-5785 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5930-01-170-5785 contain precious materials?
Item does not contain precious metal.
Does NSN 5930-01-170-5785 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5930-01-170-5785 was assigned to the Federal Catalog?
It was assigned 42 years ago, on Fri, Jan 27, 1984

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

HR11-18-272
5905-01-444-9805
Wire Wound Fixed Resistor
HR11-18-274
5905-01-444-9888
Wire Wound Fixed Resistor
HR11-18-275
5905-01-230-5095
Wire Wound Fixed Resistor
HR11-18-276
5905-01-110-0024
Wire Wound Fixed Resistor
HR11-18-277
5905-01-445-0343
Wire Wound Fixed Resistor
HR11-18-280
5905-01-445-0495
Wire Wound Fixed Resistor
HR11-18-284
5905-01-445-0778
Wire Wound Fixed Resistor
HR11-18-289
5905-01-126-5218
Wire Wound Fixed Resistor
HR11-18-292
5905-01-445-3459
Wire Wound Fixed Resistor
HR11-18-307
5905-01-188-4265
Wire Wound Fixed Resistor
HR11-18-308
5905-01-445-3548
Wire Wound Fixed Resistor
HR11-18-309
5905-01-445-4697
Wire Wound Fixed Resistor
HR11-18-310
5905-01-250-3283
Wire Wound Fixed Resistor
HR11-18-311
5905-01-445-4712
Wire Wound Fixed Resistor
HR11-18-312
5905-01-445-4971
Wire Wound Fixed Resistor