Find complete technical information, availability, and procurement data for: 5930-01-132-6098

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5930-01-132-6098 to receive an up to date pricing and availability quote by email.

5930-01-132-6098
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5930 Switches
National Stock Number
5930-01-132-6098
Item Name Code
00206
Assigment Date
06/02/1982 (44 years ago)

4.250 inches nominal distance between mounting facility centers, 8.000 inches maximum overall length, 4.750 inches nominal overall width, 0.265 inches nominal unthreaded mounting hole diameter, 3.300 inches maximum overall height

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Overall Length
8.000 inches maximum
Overall Height
3.300 inches maximum
Overall Width
4.750 inches nominal
Unthreaded Mounting Hole Diameter
0.265 inches nominal
Distance Between Mounting Facility Centers
4.250 inches nominal
Pressure Switch Type
gage
Operating Temp Rating
-34.0 celsius minimum and 71.0 celsius maximum
Mounting Method
unthreaded hole
Thread Quantity Per Inch
18 single pressure connection
Contact Action Stimulus
increase
Proof Pressure
4500.00 pounds per square inch
Nominal Thread Size
0.250 inches single pressure connection
Mounting Facility Pattern
two position in-line
Nonpile-Up Contact Arrangement
1 pole, double throw, one position momentary
Terminal Type
wire lead
Contact Load Current Rating
400.0 milliamperes resistive load and 200.0 milliamperes inductive load third voltage
Contact Load Current Rating
15.0 amperes resistive load and 15.0 amperes inductive load first voltage
Contact Load Current Rating
15.0 amperes resistive load and 15.0 amperes inductive load second voltage
Contact Adjustability
actuation point adjustable
Contact Adjustment Range
+30.00 to 100.00 actuation point pounds per square inch
Contact Adjustment Type
internal actuation point serrated nut
Contact Stimulus Rating
6.00 differential point nominal pounds per square inch
Contact Voltage Rating In Volts
125.0 ac at sea level second voltage
Contact Voltage Rating In Volts
125.0 dc at sea level third voltage
Contact Voltage Rating In Volts
480.0 ac at sea level first voltage
Pressure Connector Type
plain, threaded internal single connection
Frequency In Hertz
50.0 and 60.0 first voltage
Frequency In Hertz
50.0 and 60.0 second voltage
Thread Series Designator
npt single pressure connection

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5930-01-079-0388 No Name Available 05/01/1995

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
02100751 Pressure Switch
646GE11 Pressure Switch

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5930-01-132-6098?
The FSCG of the NSN 5930-01-132-6098 is 5930
Does the NSN 5930-01-132-6098 have a Schedule B code assigned?
Yes, the Schedule B code is 8536509065
Does NSN 5930-01-132-6098 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5930-01-132-6098 contain precious materials?
Item does not contain precious metal.
Does NSN 5930-01-132-6098 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5930-01-132-6098 was assigned to the Federal Catalog?
It was assigned 44 years ago, on Wed, Jun 2, 1982

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

843933-1-Y-4
9905-01-486-1765
Identification Plate
843933-1-Y-41
9905-01-486-1771
Identification Plate
843933-1-Y-42
9905-01-486-1774
Identification Plate
843933-1-Y-43
9905-01-486-1768
Identification Plate
843933-1-Y-44
9905-01-486-1769
Identification Plate
843933-1-Y-45
9905-01-486-1770
Identification Plate
843933-1-Y-46
9905-01-486-1772
Identification Plate
843933-1-Y-47
9905-01-486-1773
Identification Plate
843933-1-Y-48
9905-01-486-1778
Identification Plate
843933-1-Y-5
9905-01-486-1775
Identification Plate
843933-1-Y-50
9905-01-486-1777
Identification Plate
843933-1-Y-51
9905-01-486-1776
Identification Plate
843933-1-Y-52
9905-01-486-1779
Identification Plate
843933-1-Y-53
9905-01-486-1780
Identification Plate
843933-1-Y-54
9905-01-486-1782
Identification Plate