1. Home /
  2. Catalog /
  3. Switches /
  4. 5930-00-780-4637

5930-00-780-4637

Find complete technical information, availability, and procurement data for: 5930-00-780-4637

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5930-00-780-4637 to receive an up to date pricing and availability quote by email.

5930-00-780-4637
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5930 Switches
National Stock Number
5930-00-780-4637
Item Name Code
02134
Assigment Date
01/01/1962 (64 years ago)

1.042 inches maximum overall height, 2a single mounting facility thread class, 1.950 inches nominal overall length, 0.240 inches minimum and 0.260 inches maximum single mounting facility thread length, shock resistant hazardous locations/environmental protection

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Thread Class
2a single mounting facility
Thread Length
0.240 inches minimum and 0.260 inches maximum single mounting facility
Hazardous Locations/Environmental Protection
shock resistant
Overall Length
1.950 inches nominal
Overall Height
1.042 inches maximum
Overall Width
0.940 inches nominal
First Flat Length
0.280 inches nominal single actuator
Shaft Diameter
0.248 inches minimum and 0.250 inches maximum single actuator
Shaft Length
0.490 inches nominal single actuator
Nonturn Device Radius
0.380 inches nominal at 3:00 o'clock
Individual Section Quantity
2
Nonturn Device Type
tab at 3:00 o'clock
Operating Temp Range
-65.0 to 125.0 celsius
Switch Contact Basic Design
nonpile-up symmetrical
Pole Quantity
2 each section rear
Throw Quantity
4 each section rear
Mounting Method
threaded bushing single mounting facility
Nominal Thread Size
0.375 inches single mounting facility
Contact Voltage Rating In Volts
115.0 ac at sea level
Contact Voltage Rating In Volts
28.0 dc at sea level
Switch Actuator Indexing Position Quantity
4 single actuator
Shaft Type
round, v flatted single actuator
Terminal Type
tab, solder lug
Contact Switching Action
breaks before makes 2nd section rear
Contact Switching Action
makes before breaks 1st section rear
Switch Actuator Positioning Increment
30.0 degrees single actuator
Switch Actuator Stop Device Type
fixed stop single actuator
Contact Load Current Rating
100.0 milliamperes resistive load ac at sea level
Contact Load Current Rating
200.0 milliamperes resistive load and 20.0 milliamperes inductive load dc at sea level
Precious Material And Location
terminal surfaces gold and contacts silver
Precious Material
gold and silver
Style Designator
circular wafer, bushing mount
Thread Series Designator
unef single mounting facility

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
138933-01 Rotary Switch
5-26491-761 Rotary Switch

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5930-00-780-4637?
The FSCG of the NSN 5930-00-780-4637 is 5930
Does the NSN 5930-00-780-4637 have a Schedule B code assigned?
Yes, the Schedule B code is 8536509020
Does NSN 5930-00-780-4637 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5930-00-780-4637 contain precious materials?
Item contains gold.
Does NSN 5930-00-780-4637 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5930-00-780-4637 was assigned to the Federal Catalog?
It was assigned 64 years ago, on Mon, Jan 1, 1962

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

KER356-4
6625-01-251-2833
Special Scale Meter
KER356-5
6625-01-251-4533
Special Scale Meter
KER356-7
6625-01-245-9500
Special Scale Meter
KER356-8
6625-01-251-2835
Special Scale Meter
KER356-9
6625-01-244-9577
Ammeter
KER3A2613SP
5910-01-087-0297
Mica Dielectric Fixed Capacitor
KER3A3443SP-2
5910-01-051-1767
Mica Dielectric Fixed Capacitor
KER3A4146SP
5910-00-038-6902
Mica Dielectric Fixed Capacitor
KER3A4465SP
5910-01-175-4983
Mica Dielectric Fixed Capacitor
KER3A5187SP
5910-01-440-2365
Mica Dielectric Fixed Capacitor
KER3A5202SP
5910-01-243-3928
Mica Dielectric Fixed Capacitor
KER3A5335SP
5910-01-282-8746
Pulse Capacitor
KER3A7416SP
5910-01-473-1328
Mica Dielectric Fixed Capacitor
KER450119
6520-01-480-7978
Dental Endodontic Ir Syringe Tip
KER60471
6520-01-388-8678
Pathfinder