12705-2

View detailed technical data, stock status, and sourcing information for: 12705-2

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part 12705-2 to receive an up to date pricing and availability quote by email.

12705-2
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5930 Switches
National Stock Number
5930-00-077-0194
Item Name Code
00451
Assigment Date
01/01/1963 (63 years ago)

A switch that is actuated by changes in ambient temperature. Excludes:circuit breaker; control, temperature (as modified); fuse (as modified); protector, thermal-overload, electrical motor; relay, thermal; and thermostat, flow control. See also control, temperature (as modified) and regulator, temperature (as modified).

0.618 inches minimum and 0.625 inches maximum body diameter, vibration resistant hazardous locations/environmental protection, 0.500 inches nominal single threaded bushing thread length, 2a single threaded bushing thread class, 5.280 inches nominal overall length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Thread Class
2a single threaded bushing
Thread Length
0.500 inches nominal single threaded bushing
Hazardous Locations/Environmental Protection
vibration resistant
Overall Length
5.280 inches nominal
Body Diameter
0.618 inches minimum and 0.625 inches maximum
Body Length
4.060 inches nominal
Temp Sensing Element Type
expanding shell
Width Across Flats
1.000 inches nominal
Mounting Method
threaded bushing
Contact Action Stimulus
increase
Nominal Thread Size
0.875 inches single threaded bushing
Nonpile-Up Contact Arrangement
1 pole, single throw, normally closed, momentary action
Terminal Type
tab w/screw
Contact Load Current Rating
5.0 amperes resistive load second voltage
Contact Load Current Rating
10.0 amperes resistive load first voltage
Contact Load Current Rating
2.0 amperes resistive load third voltage
Contact Adjustability
actuation point adjustable, preset and deactuation point adjustable, preset
Contact Adjustment Range
-100.00 to 400.00 actuation point degrees fahrenheit and -100.00 to 400.00 deactuation point degrees fahrenheit
Contact Adjustment Type
external actuation point screw and external deactuation point screw
Contact Stimulus Rating
275.00 actuation point nominal degrees fahrenheit and 263.00 deactuation point nominal degrees fahrenheit
Contact Voltage Rating In Volts
115.0 dc at sea level third voltage
Contact Voltage Rating In Volts
120.0 ac at sea level first voltage
Contact Voltage Rating In Volts
240.0 ac at sea level second voltage
Media For Which Designed
gas or liquid
Style Designator
cylindrical w/flange
Thread Series Designator
unf single threaded bushing

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
12705-1 Thermostatic Switch
12705-2 Thermostatic Switch
18420-101-275 Thermostatic Switch

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5930-00-077-0194?
The FSCG of the NSN 5930-00-077-0194 is 5930
Does the NSN 5930-00-077-0194 have a Schedule B code assigned?
Yes, the Schedule B code is 9032100000
Does NSN 5930-00-077-0194 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5930-00-077-0194 contain precious materials?
Precious metal content is unknown
Does NSN 5930-00-077-0194 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5930-00-077-0194 was assigned to the Federal Catalog?
It was assigned 63 years ago, on Tue, Jan 1, 1963

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

140803-1
5995-01-088-2721
Radio Frequency Cable Assembly
14080311-6
5962-01-301-1670
Digital Microcircuit
140804
5315-01-486-2021
Headed Straight Pin
140804-01
6620-00-754-4914
Converterxfrequency
140804-1
5995-01-088-2722
Radio Frequency Cable Assembly
140804HF303
5340-01-579-3642
Spacing Threaded Standoff
140805-01
6620-00-753-8881
Rack Assy
1408050
4710-00-880-9927
Metallic Tube
14080577C01
5965-01-501-1106
Microphone Boot
1408059
3040-01-439-5571
Straight Shaft
140806-1
1680-00-483-9670
Aircraft Survival Kit Field Pack
1408061
3040-01-439-5778
Shouldered Shaft
14080648-5
5962-01-381-4716
Memory Microcircuit
1408067
4720-01-438-2459
Nonmetallic Hose Assembly
1408068
4720-01-438-2460
Nonmetallic Hose Assembly