JJC94269A

View detailed technical data, stock status, and sourcing information for: JJC94269A

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part JJC94269A to receive an up to date pricing and availability quote by email.

JJC94269A
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5905 Resistor
National Stock Number
5905-00-480-5235
Item Name Code
37405
Assigment Date
09/11/1970 (55 years ago)

2.437 inches maximum overall length, 1.156 inches maximum body diameter, 2 section quantity, not established reliability indicator, cylindrical bushing mounted body style

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Section Quantity
2
Body Style
cylindrical bushing mounted
Reliability Indicator
not established
Overall Length
2.437 inches maximum
Body Diameter
1.156 inches maximum
Shaft Diameter
0.126 inches minimum and 0.250 inches maximum
Shaft Length
0.750 inches minimum and 1.125 inches maximum
Mounting Bushing Length
0.375 inches maximum
Body Length
1.312 inches maximum
Body Inside Diameter
0.132 inches maximum
Overall Diameter
1.156 inches maximum
Shaft Style
round
Actuator Type
dual concentric
Effective Electrical Rotation In Deg Angular Rotation
312.0 nominal
Maximum Starting Torque
6.00 inch-ounces
Maximum Running Torque
1.00 inch-ounces
Maximum Stop Torque
192.00 inch-ounces
Nonturn Device Radius
0.536 inches maximum
Mechanical Backlash In Deg Angular Rotation
3.0
Screw Thread Diameter
0.375 inches nominal
Screw Thread Series Designator
unef
Screw Thread Quantity Per Inch
32.0
Mounting Method
standard bushing
Electrical Resistance Per Section
150.0 kilohms 1st section and 2.0 megohms 2nd section
Rotary Actuator Travel In Angular Deg
312.0 nominal
Resistance Temp Characteristic Range Per Section In Percent
+0.0 to 4.0 -25 deg celsius 1st section and +0.0 to 8.0 -55 deg celsius 1st section and -3.0 to 3.0 85 deg celsius 1st section and +0.0 to 2.0 0 deg celsius 1st section and +0.0 to 6.0 120 deg celsius 1st section and +0.0 to 10.0 -55 deg celsius 2nd section and +0.0 to 2.5 0 deg celsius 2nd section and -3.5 to 3.5 85 deg celsius 2nd section and +0.0 to 5.0 -25 deg celsius 2nd section and +0.0 to 7.5 120 deg celsius 2nd section
Ambient Temp In Deg Celsius Per Section At Zero Percent Rated Power
120.0 all sections
Device Design Type
nonturn at 9 oclock
Terminal Location
radially positioned over less than half the circumference
Power Dissipation Rating Per Section In Watts
2.0 free air all sections
Resistance Tolerance Per Section In Percent
-20.0 to 20.0 all sections
Actuator Travel Control Feature
stops
Ambient Temp In Deg Celsius Per Section At Full Rated Power
70.0 all sections
Terminal Type And Quantity
6 tab, solder lug

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5905-00-111-8474 No Name Available 02/01/1978

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
311-0478-01 Resistor,variable,nonwire Wound,
D470-4/CM39981 Resistor,variable,nonwire Wound,
JJC94269A Resistor,variable,nonwire Wound,

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5905-00-480-5235?
The FSCG of the NSN 5905-00-480-5235 is 5905
Does the NSN 5905-00-480-5235 have a Schedule B code assigned?
Yes, the Schedule B code is 8533400080
Does NSN 5905-00-480-5235 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5905-00-480-5235 contain precious materials?
Precious metal content is unknown
Does NSN 5905-00-480-5235 contain hazardous materials?
Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
When the NSN 5905-00-480-5235 was assigned to the Federal Catalog?
It was assigned 55 years ago, on Fri, Sep 11, 1970

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

03-000-29
6525-01-504-4550
Plate and Cassette
03-000-30
6525-01-504-4551
Cassette and Plate
03.000.301S
6515-01-653-3768
Power Bone Saw Blade
03-000-31
6525-01-504-4552
Cassette and Plate
03-000-32
6525-01-504-4553
Cassette and Plate
03.000.320S
6515-01-655-8525
Power Bone Saw Blade
03.000.325S
6515-01-655-8532
Power Bone Saw Blade
03-000-34
6525-01-504-4554
Cassette and Plate
03-000-35
6525-01-504-4555
Stitching Cassette Plate Kit
03-000-36
6525-01-504-4824
Cassette Holder
03-000-38
6525-01-504-4826
X-Ray Apparatus Control Unit
03-000-40
6525-01-504-4829
Auto Collima Interface and Cable
03-000-43
6525-01-504-4838
Stitching Software
03-000-46
6525-01-504-4906
Computed Radiography System
03-000-47
6525-01-504-4907
Computed Radiography System