1. Home /
  2. Catalog /
  3. Resistor /
  4. 5905-00-080-4875

5905-00-080-4875

Find complete technical information, availability, and procurement data for: 5905-00-080-4875

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5905-00-080-4875 to receive an up to date pricing and availability quote by email.

5905-00-080-4875
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5905 Resistor
National Stock Number
5905-00-080-4875
Item Name Code
37405
Assigment Date
01/01/1963 (63 years ago)

A resistor in which a sliding or rolling contact moves over an exposed area of the resistive element to change the ohmic value of the output. The functional tolerance (linearity), if given, of the output is greater than plus or minus 1 percent on linear outputs. Specified outputs such as sine, cosine, tangent, and the like, shall be considered to be precision. For items having manually positioned taps designed to be set and fixed prior to use, see resistor, adjustable. For items with step by step variation, see rheostat and resistor, step by step. For tandem-mounted items designed to function together as an attenuator (and rated accordingly), see attenuator, variable. Excludes:resistor (1), variable, wire wound, nonprecision; resistor (1), variable, nonwire wound precision; and resistor (1), variable, wire wound, precision.

cylindrical bushing mounted body style, 1.203 inches nominal overall length, not established reliability indicator, 0.484 inches minimum and 0.516 inches maximum body diameter, 1 section quantity

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Section Quantity
1
Body Style
cylindrical bushing mounted
Reliability Indicator
not established
Overall Length
1.203 inches nominal
Body Diameter
0.484 inches minimum and 0.516 inches maximum
Shaft Diameter
0.124 inches minimum and 0.126 inches maximum
Shaft Length
0.500 inches nominal
Mounting Bushing Length
0.375 inches nominal
Body Length
0.469 inches maximum
Overall Diameter
0.484 inches minimum and 0.516 inches maximum
Shaft Style
round, slotted
Actuator Type
single shaft
Effective Electrical Rotation In Deg Angular Rotation
295.0 nominal
Maximum Stop Torque
64.00 inch-ounces
Nonturn Device Radius
0.240 inches minimum and 0.250 inches maximum
Mechanical Backlash In Deg Angular Rotation
3.0
Screw Thread Diameter
0.250 inches nominal
Screw Thread Series Designator
unef
Screw Thread Quantity Per Inch
32.0
Mounting Method
locking bushing
Electrical Resistance Per Section
1.0 megohms single section
Rotary Actuator Travel In Angular Deg
295.0 nominal
Resistance Temp Characteristic Range Per Section In Percent
+0.0 to 10.0 -55 deg celsius single section and +0.0 to 5.0 -25 deg celsius single section and +0.0 to 2.5 0 deg celsius single section and -3.5 to 3.5 85 deg celsius single section and +0.0 to 7.5 120 deg celsius single section
Ambient Temp In Deg Celsius Per Section At Zero Percent Rated Power
150.0 single section
Device Design Type
nonturn at 10:30 oclock
Terminal Location
rear end
Power Dissipation Rating Per Section In Watts
0.8 heat sink single section
Resistance Tolerance Per Section In Percent
-10.0 to 10.0 single section
Actuator Travel Control Feature
stops
Ambient Temp In Deg Celsius Per Section At Full Rated Power
70.0 single section
Terminal Type And Quantity
3 tab, solder lug

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5905-00-682-0227 No Name Available 09/13/1968
5905-00-683-5027 No Name Available 09/11/1968

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
LA1M032S105UC Resistor,variable,nonwire Wound,

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5905-00-080-4875?
The FSCG of the NSN 5905-00-080-4875 is 5905
Does the NSN 5905-00-080-4875 have a Schedule B code assigned?
Yes, the Schedule B code is 8533400080
Does NSN 5905-00-080-4875 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5905-00-080-4875 contain precious materials?
Precious metal content is unknown
Does NSN 5905-00-080-4875 contain hazardous materials?
Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
When the NSN 5905-00-080-4875 was assigned to the Federal Catalog?
It was assigned 63 years ago, on Tue, Jan 1, 1963

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

472-MEDCHEST3-8D
8145-01-708-3736
E Shipping and Storage Container
472-MEDCHEST3-8D-137
6545-01-570-2004
Medical Instrument and Supp Case
472-MEDCHEST3-8D-137,OLIVE DRAB
6545-01-607-3488
Medical Instrument and Supp Case
472-MEDCHEST3-8D-182
6545-01-533-8207
Medical Instrument and Supp Case
472-MEDCHEST4-182
6545-01-549-3724
Medical Instrument and Supp Case
472-MEDCHEST5-182
6545-01-549-3729
Medical Instrument and Supp Case
472-MEDCHEST6-182
6545-01-545-6291
Medical Instrument and Supp Case
472-MEDCHEST7-137
6545-01-611-7713
Medical Instrument and Supp Case
472-MEDCHEST7-182
6545-01-545-6369
Medical Instrument and Supp Case
472-MEDCHEST7-SHLFKT
8145-01-579-0163
Shipping and St Modification Kit
472-MEDLEGSET
6515-01-545-6329
Leg Case Table Kit Assembly
472-MINIGUN-S-137
8140-01-563-4817
M Shipping and Storage Container
472-MK19-C-137
8140-01-565-3687
M Shipping and Storage Container
472-P
6210-01-656-8869
Lighting Fixture
472-PF
6210-01-262-1597
Lighting Fixture