5945-00-941-1905
Find complete technical information, availability, and procurement data for: 5945-00-941-1905
DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5945-00-941-1905 to receive an up to date pricing and availability quote by email.
A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes:transformer (1), pulse.
0.687 inches nominal single mounting facility center to center distance between mounting facilities parallel to width, 2a single mounting facility thread class, 1.531 inches maximum overall length, 1.187 inches nominal single mounting facility center to center distance between mounting facilities parallel to length, right-hand single mounting facility thread direction
Product Characteristics
Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.
- Thread Class
- 2a single mounting facility
- Thread Direction
- right-hand single mounting facility
- Overall Length
- 1.531 inches maximum
- Center To Center Distance Between Mounting Facilities Parallel To Length
- 1.187 inches nominal single mounting facility
- Center To Center Distance Between Mounting Facilities Parallel To Width
- 0.687 inches nominal single mounting facility
- Overall Height
- 2.624 inches maximum
- Overall Width
- 1.130 inches maximum
- Case Material
- unable to decode
- Environmental Protection
- hermetic
- Fragility Factor
- moderately rugged
- Frequency In Hertz
- 400.0 nominal
- Winding Quantity
- 1
- Purpose For Which Designed
- general
- Coil Quantity
- 1
- Duty Type
- continuous
- Arc Quenching Method
- air
- Mounting Facility Type And Quantity
- unable to decode
- Storage Type
- general purpose warehouse
- Cubic Measure
- 4.539 cubic inches
- Thread Quantity Per Inch
- 32 single mounting facility
- Nominal Thread Size
- 0.138 inches single mounting facility
- Mounting Facility Pattern
- rectangular single mounting facility
- Nonpile-Up Main Contact Arrangement
- 4 pole, double throw, one position momentary
- Time Delay
- 0.025 seconds maximum fixed operate time
- Time Delay
- 0.05 seconds maximum fixed release time
- Operating Voltage Rating And Type At Specified Temp
- 115.0 volts ac 25 deg celsius single winding
- Main Contact Load Current Rating At Maximum Rated Voltage
- 1.5 amperes ac and 1.5 amperes dc motor load
- Main Contact Load Current Rating At Maximum Rated Voltage
- 3.0 amperes ac and 3.0 amperes dc inductive load
- Main Contact Load Current Rating At Maximum Rated Voltage
- 5.0 amperes ac and 5.0 amperes dc resistive load
- Main Contact Load Current Rating At Maximum Rated Voltage
- 800.0 milliamperes ac and 800.0 milliamperes dc lamp load
- Main Contact Maximum Voltage Rating In Volts
- 115.0 ac and 28.0 dc
- Test Data Document
- "81349-mil-r-6106 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
- Thread Series Designator
- unc single mounting facility
- Terminal Type And Quantity
- 14 wire hook all functions
- Specification/Standard Data
- 96906-ms25268 government standard
Related Parts
This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:
| Part Number | Name |
|---|---|
| MS25268-A1 | Electromagnetic Relay |
FAQs
Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.
What is the FSCG of the NSN 5945-00-941-1905?
Does the NSN 5945-00-941-1905 have a Schedule B code assigned?
Does NSN 5945-00-941-1905 require demilitarization?
Does NSN 5945-00-941-1905 contain precious materials?
Does NSN 5945-00-941-1905 contain hazardous materials?
When the NSN 5945-00-941-1905 was assigned to the Federal Catalog?
Professional Distribution
Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.
- ITAR Registered
- DDTC Registered
- HAZMAT Certified
- AS9120 Quality Standards
- 100% Quality Inspections
You May Also Like
Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.
Pricing
Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information: