507624-264

View detailed technical data, stock status, and sourcing information for: 507624-264

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part 507624-264 to receive an up to date pricing and availability quote by email.

507624-264
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5962 Electronic Microcircuits
National Stock Number
5962-01-109-4224
Item Name Code
31778
Assigment Date
03/14/1981 (45 years ago)

0.660 inches minimum and 0.785 inches maximum body length, 0.140 inches minimum and 0.185 inches maximum body height, 1.0 watts maximum power dissipation rating, -55.0 to 125.0 celsius operating temp range, 0.220 inches minimum and 0.280 inches maximum body width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Length
0.660 inches minimum and 0.785 inches maximum
Body Width
0.220 inches minimum and 0.280 inches maximum
Body Height
0.140 inches minimum and 0.185 inches maximum
Maximum Power Dissipation Rating
1.0 watts
Operating Temp Range
-55.0 to 125.0 celsius
Storage Temp Range
-65.0 to 150.0 celsius
Features Provided
hermetically sealed and monolithic and positive outputs
Inclosure Material
ceramic and glass
Inclosure Configuration
dual-in-line
Input Circuit Pattern
quad 2 input
Design Function And Quantity
4 receiver, line
Case Outline Source And Designator
t0-116 joint electron device engineering council
Terminal Surface Treatment
solder
Voltage Rating And Type Per Characteristic
30.0 volts maximum power source
Time Rating Per Chacteristic
85.00 nanoseconds maximum propagation delay time, low to high level output and 50.00 nanoseconds maximum propagation delay time, high to low level output
Terminal Type And Quantity
14 printed circuit

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5962-00-390-0879 No Name Available 04/01/1992
5962-01-034-1498 No Name Available 05/01/2008
5962-01-057-0652 No Name Available 06/04/2008
5962-01-142-5301 No Name Available 07/01/1991

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
0N332848-1 Linear Microcircuit
115271-1 Linear Microcircuit
1302664-1 Linear Microcircuit
139-085-189 Linear Microcircuit
15-512091-1 Linear Microcircuit
28022680 Linear Microcircuit
34 875-016 Linear Microcircuit
3594621-1 Linear Microcircuit
477-1139-002 Linear Microcircuit
507624-264 Linear Microcircuit
507933-12 Linear Microcircuit
55189A Linear Microcircuit
6011299-001 Linear Microcircuit
704AS6930 Linear Microcircuit
935452 Linear Microcircuit
989C271H01 Linear Microcircuit
AM2617DM-B Linear Microcircuit
DMS 81101B Linear Microcircuit
ES5363-02 Linear Microcircuit
I17-0001-000 Linear Microcircuit
SN75189 Linear Microcircuit
SN75189A Linear Microcircuit
SNC55189AJ Linear Microcircuit
SNJ55189AJ Linear Microcircuit
SNJ55189AJ-00 Linear Microcircuit
SNJ55189JA Linear Microcircuit

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5962-01-109-4224?
The FSCG of the NSN 5962-01-109-4224 is 5962
Does the NSN 5962-01-109-4224 have a Schedule B code assigned?
Yes, the Schedule B code is 8542900000
Does NSN 5962-01-109-4224 require demilitarization?
"commerce control list items (ccli) - mut to the point of scrap required outside the united states. Inside the united states, mut is required when the demil integrity code (ic) is "3" and mut is not required when the demic is "6" (note 8)"
Does NSN 5962-01-109-4224 contain precious materials?
Item does not contain precious metal.
Does NSN 5962-01-109-4224 contain hazardous materials?
Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
When the NSN 5962-01-109-4224 was assigned to the Federal Catalog?
It was assigned 45 years ago, on Sat, Mar 14, 1981

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

10BCXXX0X60E1BBXXC01
6680-00-250-1965
Diff Fluid Flow Indicating Meter
10BCXXX0X60E1BBXXX01
6680-00-250-1965
Diff Fluid Flow Indicating Meter
10BCXXX0X70A5BBAXX01
6680-01-012-0997
Diff Fluid Flow Indicating Meter
10BCXXX0X75F1BBAXX01
6685-00-512-0992
Dial Indicatin Differential Gage
10BCXXX0X75F1BBAXX02
6685-00-512-0992
Dial Indicatin Differential Gage
10BCXXX0X80A1BBAXX01
6680-01-281-7273
Diff Fluid Flow Indicating Meter
10BCXXX0X80A5BBAXX02
6680-00-069-4994
Diff Fluid Flow Indicating Meter
10BCXXX0X85F1BAAXC01
5930-00-484-4180
Pressure Switch
10BCXXX0X85F1BAAXX01
5930-00-484-4180
Pressure Switch
10BCXXX0X85F1BBAXC01
6685-00-146-9358
Dial Indicatin Differential Gage
10BCXXX0X85F1BBAXX01
6685-00-146-9358
Dial Indicatin Differential Gage
10BCXXX0X86A5XBAXX01
6685-01-311-3295
Dial Indicating Pressure Gage
10BCXXX0XX5E1BBAXX01
6685-01-035-5453
Dial Indicatin Differential Gage
10BDR64
5998-01-520-6289
Circuit Card Assembly
10BDXXX0X43A4CBXXX01
6680-00-847-7620
Diff Fluid Flow Indicating Meter