1. Home /
  2. Catalog /
  3. Filters and Networks /
  4. 5915-01-208-0657

5915-01-208-0657

Find complete technical information, availability, and procurement data for: 5915-01-208-0657

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5915-01-208-0657 to receive an up to date pricing and availability quote by email.

5915-01-208-0657
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5915 Filters and Networks
National Stock Number
5915-01-208-0657
Item Name Code
00765
Assigment Date
05/08/1985 (41 years ago)

8.750 inches nominal overall length, 5.500 inches nominal distance between centerlines of mounting facilities parallel to body length, 3.000 inches nominal body height, 4.000 inches nominal body width, 6.500 inches nominal body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Overall Length
8.750 inches nominal
Body Length
6.500 inches nominal
Body Width
4.000 inches nominal
Body Height
3.000 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
5.500 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
3.000 inches nominal
Operating Temp Range
-55.0 to 85.0 celsius
Source Impedance Rating Per Function
5.0 ohms 1st radio interference 1st function
Source Impedance Rating Per Function
5.0 ohms 2nd radio interference 2nd function
Source Impedance Rating Per Function
5.0 ohms 3rd radio interference 3rd function
Source Impedance Rating Per Function
5.0 ohms 4th radio interference 4th function
Load Impedance Per Function
5.0 ohms 1st radio interference 1st function
Load Impedance Per Function
5.0 ohms 2nd radio interference 2nd function
Load Impedance Per Function
5.0 ohms 3rd radio interference 3rd function
Load Impedance Per Function
5.0 ohms 4th radio interference 4th function
Power Line Frequency Rating Per Function In Hertz
440.0 1st radio interference 1st function
Power Line Frequency Rating Per Function In Hertz
440.0 2nd radio interference 2nd function
Power Line Frequency Rating Per Function In Hertz
440.0 3rd radio interference 3rd function
Power Line Frequency Rating Per Function In Hertz
440.0 4th radio interference 4th function
Operating Current Rating Per Function In Amps
10.0 1st radio interference 1st function
Operating Current Rating Per Function In Amps
10.0 2nd radio interference 2nd function
Operating Current Rating Per Function In Amps
10.0 3rd radio interference 3rd function
Operating Current Rating Per Function In Amps
10.0 4th radio interference 4th function
Maximum Voltage Drop Per Function
500.0 millivolts ac 1st radio interference and 500.0 millivolts dc 1st radio interference 1st function
Maximum Voltage Drop Per Function
500.0 millivolts ac 3rd radio interference and 500.0 millivolts dc 3rd radio interference 3rd function
Maximum Voltage Drop Per Function
500.0 millivolts ac 2nd radio interference and 500.0 millivolts dc 2nd radio interference 2nd function
Maximum Voltage Drop Per Function
500.0 millivolts ac 4th radio interference and 500.0 millivolts dc 4th radio interference 4th function
Principal Circuitry Type Per Function
capacitance-inductance 4th radio interference 4th function
Principal Circuitry Type Per Function
capacitance-inductance 1st radio interference 1st function
Principal Circuitry Type Per Function
capacitance-inductance 2nd radio interference 2nd function
Principal Circuitry Type Per Function
capacitance-inductance 3rd radio interference 3rd function
Maximum Temp Rise
25.0 celsius
Mounting Facility Screw Thread Series Designator
unf
Inclosure Type
hermetically sealed
Mounting Facility Type And Quantity
4 threaded hole all functions
Functional Terminal Type And Quantity
1 threaded stud ground 3rd function
Functional Terminal Type And Quantity
4 wire lead input 1st function
Functional Terminal Type And Quantity
4 wire lead output 2nd function
Operating Voltage Rating And Type Per Function
130.0 volts ac 2nd radio interference and 400.0 volts dc 2nd radio interference 2nd function
Operating Voltage Rating And Type Per Function
130.0 volts ac 3rd radio interference and 400.0 volts dc 3rd radio interference 3rd function
Operating Voltage Rating And Type Per Function
130.0 volts ac 1st radio interference and 400.0 volts dc 1st radio interference 1st function
Operating Voltage Rating And Type Per Function
130.0 volts ac 4th radio interference and 400.0 volts dc 4th radio interference 4th function
Nominal Thread Size
0.190 inches
Body Material
metal
Style Designator
rectangular terminal/terminals on opposite surfaces

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
3593532-1 Radio Frequency Interfere Filter
E-1975 Radio Frequency Interfere Filter
RF10364 Radio Frequency Interfere Filter

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5915-01-208-0657?
The FSCG of the NSN 5915-01-208-0657 is 5915
Does the NSN 5915-01-208-0657 have a Schedule B code assigned?
Yes, the Schedule B code is 8527995030
Does NSN 5915-01-208-0657 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5915-01-208-0657 contain precious materials?
Item does not contain precious metal.
Does NSN 5915-01-208-0657 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5915-01-208-0657 was assigned to the Federal Catalog?
It was assigned 41 years ago, on Wed, May 8, 1985

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

CR-65/U37.851852MHZ
5955-00-082-4332
Quartz Crystal Unit
CR-65/U37.888889MHZ
5955-00-082-4333
Quartz Crystal Unit
CR-65/U37.888890MHZ
5955-00-082-4333
Quartz Crystal Unit
CR-65/U37.925930MHZ
5955-00-082-4334
Quartz Crystal Unit
CR-65/U37.955550MHZ
5955-00-950-5747
Quartz Crystal Unit
CR-65/U37.962960MHZ
5955-00-082-4335
Quartz Crystal Unit
CR-65/U37.966666MHZ
5955-01-010-1253
Quartz Crystal Unit
CR-65/U37.970370MHZ
5955-00-978-4696
Quartz Crystal Unit
CR-65/U37.992590MHZ
5955-01-240-7504
Quartz Crystal Unit
CR-65/U37.996290MHZ
5955-00-952-5666
Quartz Crystal Unit
CR-65/U38.000000MHZ
5955-00-686-8772
Quartz Crystal Unit
CR-65/U38.003710MHZ
5955-00-952-5667
Quartz Crystal Unit
CR-65/U38.007410MHZ
5955-01-240-6464
Quartz Crystal Unit
CR-65/U38.029630MHZ
5955-00-952-5668
Quartz Crystal Unit
CR-65/U38.033330MHZ
5955-00-952-5669
Quartz Crystal Unit