1. Home /
  2. Catalog /
  3. Filters and Networks /
  4. 5915-01-159-0116

5915-01-159-0116

Find complete technical information, availability, and procurement data for: 5915-01-159-0116

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5915-01-159-0116 to receive an up to date pricing and availability quote by email.

5915-01-159-0116
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5915 Filters and Networks
National Stock Number
5915-01-159-0116
Item Name Code
00209
Assigment Date
08/01/1983 (43 years ago)

An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes:items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes:filter, low pass and suppressor, ignition interference. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see filter, band suppression and filter, band pass. See also limiter, electrical noise.

2.140 inches nominal body length, 1.840 inches nominal body width, 2.890 inches nominal overall length, 0.140 inches nominal unthreaded mounting hole diameter, 0.790 inches nominal body height

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Overall Length
2.890 inches nominal
Body Length
2.140 inches nominal
Body Width
1.840 inches nominal
Body Height
0.790 inches nominal
Unthreaded Mounting Hole Diameter
0.140 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.515 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.375 inches nominal
Operating Temp Range
-40.0 to 60.0 celsius
Reference Frequency Per Function
1.09 gigahertz blank
Input Impedance Per Function W/Load
50.0 ohms blank
Output Impedance Per Function W/Source Across Input
50.0 ohms blank
Voltage Standing Wave Ratio Per Function
1.5 blank
Inclosure Type
encased
Mounting Facility Type And Quantity
4 unthreaded hole
Insertion Loss At Reference Frequency Per Function In Decibels
25.0 blank
Functional Terminal Type And Quantity
1 connector, receptacle input 1st function
Functional Terminal Type And Quantity
1 connector, receptacle output 2nd function
Specified Frequencies Of Discrimination Per Function
960.00 megahertz blank and 1.04 gigahertz blank and 1.11 gigahertz blank and 1.14 gigahertz blank
Body Material
metal
Frequency Band Width Per Function
1.04 gigahertz blank and 1.11 gigahertz blank
Discrimination At Specified Frequencies Per Function In Decibels
25.0 minimum blank and 1.6 maximum blank 1st function
Voltage Standing Wave Ratio Frequency Limits Per Function
1.04 gigahertz blank and 1.1 gigahertz blank
Special Features
unpackaged unit weight: lb2.000
Style Designator
rectangular terminal/terminals on opposite surfaces

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
03810 Band Pass Filter
504-606-02 Band Pass Filter
733023-1 Band Pass Filter
FX20-0756-01 Band Pass Filter

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5915-01-159-0116?
The FSCG of the NSN 5915-01-159-0116 is 5915
Does the NSN 5915-01-159-0116 have a Schedule B code assigned?
Yes, the Schedule B code is 8527995030
Does NSN 5915-01-159-0116 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5915-01-159-0116 contain precious materials?
Item does not contain precious metal.
Does NSN 5915-01-159-0116 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5915-01-159-0116 was assigned to the Federal Catalog?
It was assigned 43 years ago, on Mon, Aug 1, 1983

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

92-3-23-114 MSP
6240-01-366-9670
Incandescent Lamp
92-3-23-117 MSP
6515-01-360-5813
Dispensing Pin
92-3-23-123 MSP
6515-01-362-8304
Endoscopic Forceps
92-3-23-124
6515-01-363-4494
Endoscopic Hernia Instrument
92-3-23-130 MSP
6515-01-361-6917
Bone Screw
92-3-23-131 MSP
6515-01-360-8989
Bone Screw
92-3-23-133 AH
6515-01-360-8940
Surgical Absorbable Suture
92-3-23-135 MSP
6515-01-361-7833
Biopsy Needle
92-3-23-138 MSP
6515-01-362-8305
Endoscopic Shears
92-3-23-144 MSP
6515-01-361-5669
Pharmaceutical Diluting Tube
92-3-23-152 AH
6515-01-360-4675
Surgical Absorbable Suture
92-3-23-160 DE
6515-01-359-5181
Tracheal Tube Stylet
92-3-23-175 MSP
8450-01-360-3621
Knit Cap
92-3-23-22 MSP
6515-01-360-2139
Pulmonary Machin Bacteria Filter
92-3-23-40 MSP
6530-01-362-8349
Sterilization Indicating Card