6625-01-349-0258

Find complete technical information, availability, and procurement data for: 6625-01-349-0258

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 6625-01-349-0258 to receive an up to date pricing and availability quote by email.

6625-01-349-0258
Federal Supply Group
Instruments and Laboratory Equipment
National Stock Number
6625-01-349-0258
Item Name Code
16450
Assigment Date
11/19/1991 (34 years ago)

An instrument which measures electric current and is calibrated and marked in amperes or any multiple and/or submultiple thereof. The value may be expressed by means of a pointer and calibrated dial or a digital readout display. For current detecting type of devices, see galvanometer.

2.813 inches nominal overall height, dc circuit current for which designed, 2.813 inches nominal overall width, 25 single indicator single range scale division quantity, 2.282 inches nominal overall length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Circuit Current For Which Designed
dc
Overall Length
2.282 inches nominal
Overall Height
2.813 inches nominal
Overall Width
2.813 inches nominal
Scale Division Quantity
25 single indicator single range
Mounting Stud Length
1.219 inches nominal
Environmental Protection
shock resistant and vibration resistant
Distance Between Mounting Facility Centers
2.784 inches minimum and 2.825 inches maximum
Furnished Items And Quantity
nut 2; washer 2
Indicator Type
dial w/pointer
Installation Design
panel
Mounting Arrangement Style
two hole/stud
Dial Scale Marking Color
black single indicator single range
Accuracy In Percent
-5.0 to 5.0 at full scale single indicator single range
Panel For Which Designed
magnetic or nonmagnetic
Meter Depth Behind Mounting Flange
0.625 inches nominal
Meter Body Diameter Behind Mounting Flange
2.000 inches nominal
Movement Type
moving coil, permanent magnet
Background Color
white single indicator single range
Pointer Color
black single indicator single range
Power Source
external
Mounting Facility Type And Quantity
2 threaded stud
Scale Graduation Type
linear single indicator single range
Measurement Range
+0.0 to 25.0 amperes, dc single indicator single range
Circuit Construction Type
nonelectronic
Mounting Stud Diameter
0.190 inches nominal
Features Provided
magnetic shield and zero adjuster
Movement Suspension Method
jewel pivot base
Circuit Attachment Method And Quantity
2 threaded stud
Special Features
ruggedized
Material
steel
Nuclear Hardness Critical Feature
nonhardened
Surface Treatment
zinc
Style Designator
rectangular flush mtg
Fsc Application Data
test set,elect. equip.

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
21-132-LM Ammeter
P1DA-E20-A1S Ammeter
P1DA-E25-A1S Ammeter

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 6625-01-349-0258?
The FSCG of the NSN 6625-01-349-0258 is 6625
Does the NSN 6625-01-349-0258 have a Schedule B code assigned?
Yes, the Schedule B code is 9030908030
Does NSN 6625-01-349-0258 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 6625-01-349-0258 contain precious materials?
Item does not contain precious metal.
Does NSN 6625-01-349-0258 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 6625-01-349-0258 was assigned to the Federal Catalog?
It was assigned 34 years ago, on Tue, Nov 19, 1991

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

75-SGS-05-20
4730-01-241-2541
Filter-Strainer Fluid
75-SGS-06
4730-01-241-2542
Filter-Strainer Fluid
75-SGS-06-28
4730-01-241-2542
Filter-Strainer Fluid
75-SGS-07
4730-01-241-2543
Filter-Strainer Fluid
75-SGS-07-36
4730-01-241-2543
Filter-Strainer Fluid
75-SGS-08
4730-01-241-2544
Filter-Strainer Fluid
75-SGS-08-46
4730-01-241-2544
Filter-Strainer Fluid
75-SGS-09
4730-01-241-2545
Filter-Strainer Fluid
75-SGS-09-65
4730-01-241-2545
Filter-Strainer Fluid
75-SGS-10
4730-01-241-2546
Filter-Strainer Fluid
75-SGS-10-87
4730-01-241-2546
Filter-Strainer Fluid
75-SGS-11
4730-01-241-1450
Fluid Flow Restrictor
75-SGS-11-115
4730-01-241-1450
Fluid Flow Restrictor
75-SGS-12
4730-01-241-1451
Fluid Flow Restrictor
75-SGS-13
4730-01-241-1452
Filter-Strainer Fluid