6625-01-340-3664

Find complete technical information, availability, and procurement data for: 6625-01-340-3664

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 6625-01-340-3664 to receive an up to date pricing and availability quote by email.

6625-01-340-3664
Federal Supply Group
Instruments and Laboratory Equipment
National Stock Number
6625-01-340-3664
Item Name Code
16450
Assigment Date
06/11/1991 (35 years ago)

An instrument which measures electric current and is calibrated and marked in amperes or any multiple and/or submultiple thereof. The value may be expressed by means of a pointer and calibrated dial or a digital readout display. For current detecting type of devices, see galvanometer.

2.240 inches nominal center to center distance between mounting facilities parallel to length, 2.550 inches nominal overall length, 2.240 inches nominal center to center distance between mounting facilities parallel to width, ac circuit current for which designed, 3.000 inches nominal overall height

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Circuit Current For Which Designed
ac
Overall Length
2.550 inches nominal
Center To Center Distance Between Mounting Facilities Parallel To Length
2.240 inches nominal
Center To Center Distance Between Mounting Facilities Parallel To Width
2.240 inches nominal
Overall Height
3.000 inches nominal
Overall Width
3.000 inches nominal
Mounting Stud Length
0.530 inches nominal
Furnished Items And Quantity
nut 6; washer 6
Indicator Type
dial w/pointer
Installation Design
panel
Mounting Arrangement Style
four hole/stud rectangular/square
Frequency Response Range
+25.000 to 800.000 hertz
Sensitivity Rating
50.0 amperes
Dial Scale Marking Color
black single indicator single range
Accuracy In Percent
-2.0 to 2.0 at full scale single indicator single range
Panel For Which Designed
magnetic or nonmagnetic
Meter Depth Behind Mounting Flange
1.340 inches nominal
Meter Body Diameter Behind Mounting Flange
2.690 inches nominal
Movement Type
moving iron vane
Background Color
white single indicator single range
Pointer Color
black single indicator single range
Power Source
external
Mounting Facility Type And Quantity
4 threaded stud
Scale Graduation Type
nonlinear single indicator single range
Measurement Range
+0.0 to 50.0 amperes, ac single indicator single range
Circuit Construction Type
nonelectronic
Mounting Stud Diameter
0.112 inches nominal
Features Provided
knife edge pointer and magnetic shield and zero adjuster
Movement Suspension Method
jewel pivot base
Circuit Attachment Method And Quantity
2 threaded stud
Material
plastic phenolic
Nuclear Hardness Critical Feature
nonhardened
Style Designator
rectangular flush mtg
Fsc Application Data
elec,elect. properties measuring and test instruments

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
2153-0-50AAC Ammeter
2153-17704 Ammeter

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 6625-01-340-3664?
The FSCG of the NSN 6625-01-340-3664 is 6625
Does the NSN 6625-01-340-3664 have a Schedule B code assigned?
Yes, the Schedule B code is 9030908030
Does NSN 6625-01-340-3664 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 6625-01-340-3664 contain precious materials?
Precious metal content is unknown
Does NSN 6625-01-340-3664 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 6625-01-340-3664 was assigned to the Federal Catalog?
It was assigned 35 years ago, on Tue, Jun 11, 1991

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

825-S3800-93T
5935-01-263-5171
Electrical Receptacle Connector
825-T1800
5935-00-356-8080
Electrical Plug Connector
825-T1800A
5935-01-445-8618
Electrical Plug Connector
825-T2800M
5935-01-114-0651
Electrical Plug Connector
825-T3800
5935-01-057-0438
Electrical Plug Connector
825-T3800-15(M1)
5935-01-116-5490
Electrical Receptacle Connector
825-T3800A-75
5935-01-039-7106
Electrical Receptacle Connector
825-T3800B-75
5935-01-039-7106
Electrical Receptacle Connector
825-T5
6230-00-892-5253
Extension Light
825-UVC
6530-01-461-0313
Microporous Filtering Unit
825-YM 1IN
4820-01-216-5267
Check Valve
8250
2825-00-036-3370
Retainer With Nut
8250-0
5340-01-621-2241
Electronic Equipmen Hardware Kit
8250-0011
5998-01-060-3359
Circuit Card Assembly
8250-008
2990-00-477-2131
H Governor Actuator