6625-01-235-8922

Find complete technical information, availability, and procurement data for: 6625-01-235-8922

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 6625-01-235-8922 to receive an up to date pricing and availability quote by email.

6625-01-235-8922
Federal Supply Group
Instruments and Laboratory Equipment
National Stock Number
6625-01-235-8922
Item Name Code
16450
Assigment Date
07/08/1986 (40 years ago)

An instrument which measures electric current and is calibrated and marked in amperes or any multiple and/or submultiple thereof. The value may be expressed by means of a pointer and calibrated dial or a digital readout display. For current detecting type of devices, see galvanometer.

3000.0 dielectric withstanding voltage in volts, ac circuit current for which designed, 0.150 inches nominal mounting hole diameter, 3.500 inches nominal overall diameter, 2.625 inches nominal overall length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Circuit Current For Which Designed
ac
Dielectric Withstanding Voltage In Volts
3000.0
Overall Length
2.625 inches nominal
Mounting Hole Diameter
0.150 inches nominal
Overall Diameter
3.500 inches nominal
Environmental Protection
cold resistant and heat resistant and humidity resistant and vibration resistant
Mounting Bolt Circle Diameter
3.160 inches nominal
Furnished Items And Quantity
o ring 1; mtg hdw 3; term. hdw 2
Indicator Type
dial w/pointer
Installation Design
panel
Mounting Arrangement Style
three hole/stud bolt circle
Sensitivity Rating
5.0 amperes
Dial Scale Marking Color
black single indicator single range
Accuracy In Percent
-2.0 to 2.0 at full scale single indicator single range
Panel For Which Designed
magnetic or nonmagnetic
Meter Depth Behind Mounting Flange
1.500 inches nominal
Meter Body Diameter Behind Mounting Flange
2.800 inches nominal
Movement Type
moving iron vane
Background Color
white single indicator single range
Pointer Color
black single indicator single range
Power Source
external
Mounting Facility Type And Quantity
3 screw and 3 unthreaded hole
Scale Graduation Type
nonlinear single indicator single range
Measurement Range
+0.0 to 150.0 amperes, ac single indicator single range
Circuit Construction Type
nonelectronic
Features Provided
magnetic shield and zero adjuster
Movement Suspension Method
taut band
Circuit Attachment Method And Quantity
2 threaded stud
Special Features
ruggedized
Material
steel
Nuclear Hardness Critical Feature
nonhardened
Surface Treatment
cadmium
Style Designator
round flush mtg
Supplementary Features
transformer rated
Fsc Application Data
test set,elect. equip.

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
366-134 Ammeter
638-E726 Ammeter
85-33007 Ammeter
MK777-113 Ammeter

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 6625-01-235-8922?
The FSCG of the NSN 6625-01-235-8922 is 6625
Does the NSN 6625-01-235-8922 have a Schedule B code assigned?
Yes, the Schedule B code is 9030908030
Does NSN 6625-01-235-8922 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 6625-01-235-8922 contain precious materials?
Item does not contain precious metal.
Does NSN 6625-01-235-8922 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 6625-01-235-8922 was assigned to the Federal Catalog?
It was assigned 40 years ago, on Tue, Jul 8, 1986

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

VAB-805E
5961-01-023-9461
Diode Semiconductor Device
VAB254
5306-00-360-4466
Machine Bolt
VAB3-N05
5340-01-674-6788
Utility Resilient Mount
VAB4-N05
5340-01-666-9021
Utility Resilient Mount
VAB800H
5961-01-024-4467
Diode Semiconductor Device
VAB816
4820-00-769-0977
Valve Disk
VAB832B
4820-01-040-0184
Disk Guide
VABAAD0C-00000-000
5930-01-457-6393
Toggle Switch
VAC
4910-00-223-6481
Clutch Plate-Fl Grinding Machine
VAC-023315
5930-01-267-6570
Switch Subassembly
VAC-28-V1A-1
4120-01-509-0174
Air Conditioner
VAC-3459296-REV
5930-01-515-1413
Toggle Switch
VAC-CON V312HE 1300 SEWER TRK DU
2320-01-717-4501
Tank Truck
VAC GOOP
8030-01-369-1904
Antiseize Compound
VAC PACK 3760 P1
9330-01-252-4408
Plastic Sheet