6625-01-159-6857

Find complete technical information, availability, and procurement data for: 6625-01-159-6857

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 6625-01-159-6857 to receive an up to date pricing and availability quote by email.

6625-01-159-6857
Federal Supply Group
Instruments and Laboratory Equipment
National Stock Number
6625-01-159-6857
Item Name Code
16450
Assigment Date
08/12/1983 (43 years ago)

An instrument which measures electric current and is calibrated and marked in amperes or any multiple and/or submultiple thereof. The value may be expressed by means of a pointer and calibrated dial or a digital readout display. For current detecting type of devices, see galvanometer.

4.422 inches nominal overall height, 3.376 inches nominal center to center distance between mounting facilities parallel to length, 4.062 inches nominal overall length, ac circuit current for which designed, 3.376 inches nominal center to center distance between mounting facilities parallel to width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Circuit Current For Which Designed
ac
Overall Length
4.062 inches nominal
Center To Center Distance Between Mounting Facilities Parallel To Length
3.376 inches nominal
Center To Center Distance Between Mounting Facilities Parallel To Width
3.376 inches nominal
Overall Height
4.422 inches nominal
Overall Width
4.422 inches nominal
Scale Division Quantity
40 single indicator single range
Mounting Stud Length
0.625 inches nominal
Furnished Items And Quantity
mtg hardware 4; term. hardware
Indicator Type
dial w/pointer
Installation Design
panel
Mounting Arrangement Style
four hole/stud rectangular/square
Frequency Response Range
+0.025 to 1.000 kilohertz
Dial Scale Marking Color
black single indicator single range
Accuracy In Percent
-1.5 to 1.5 at full scale single indicator single range
Panel For Which Designed
nonmagnetic
Meter Depth Behind Mounting Flange
2.813 inches nominal
Meter Body Diameter Behind Mounting Flange
3.960 inches nominal
Movement Type
moving coil, permanent magnet
Pointer Color
black single indicator single range
Scale Graduation Type
linear single indicator single range
Measurement Range
+0.0 to 80.0 amperes, ac single indicator single range
Circuit Construction Type
nonelectronic
Features Provided
zero adjuster
Movement Suspension Method
taut band
Circuit Attachment Method And Quantity
2 threaded stud
Special Features
400 hz xfrmr required
Nuclear Hardness Critical Feature
nonhardened
Style Designator
rectangular flush mtg

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
241-0-80A-400CY Ammeter
KC-241-0-80A-400CY Ammeter

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 6625-01-159-6857?
The FSCG of the NSN 6625-01-159-6857 is 6625
Does the NSN 6625-01-159-6857 have a Schedule B code assigned?
Yes, the Schedule B code is 9030908030
Does NSN 6625-01-159-6857 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 6625-01-159-6857 contain precious materials?
Item does not contain precious metal.
Does NSN 6625-01-159-6857 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 6625-01-159-6857 was assigned to the Federal Catalog?
It was assigned 43 years ago, on Fri, Aug 12, 1983

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

MODEL NO. 39
6515-01-179-0120
Leg Calf Support
MODEL NO 408
4210-01-515-4061
Fire Extinguisher
MODEL NO. 421
6530-00-706-5100
Floor Light
MODEL NO. 421,423 & 11079
6530-00-706-5100
Floor Light
MODEL NO.44 SIZE 7
5330-01-437-8236
Gasket
MODEL NO.44 SIZE 7 GRAFOIL
5330-01-437-8236
Gasket
MODEL NO. 459AN
6520-01-442-9776
Dental Handpiece Coupler
MODEL NO. 465RN
6520-01-464-2496
Dental Handpiece Coupler
MODEL NO. 523 5/8IN OD X 10.75IN
6680-01-602-2631
Liquid Level Gage Rod
MODEL NO. 527 5/8IN OD X 10.75IN
6680-01-602-2631
Liquid Level Gage Rod
MODEL NO. 75
6530-00-962-9965
Surgical Instrument Sterilizer
MODEL NO. 76
5310-01-412-5993
Sleeve Nut
MODEL NO 80K-6
6625-01-147-0112
Test Probe
MODEL NO 8139
7025-01-430-4999
Disk Drive Unit
MODEL NO 815A NPT
3450-01-422-6154
Self-Opening Die Head