6625-01-144-7622
Find complete technical information, availability, and procurement data for: 6625-01-144-7622
DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 6625-01-144-7622 to receive an up to date pricing and availability quote by email.
"an electrically operated instrument having a zero point on its scale (usually located in the center thereof). It may not indicate units of electrical measurement. The value may be expressed by means of a pointer and calibrated dial or a digital readout display. When the indication shows zero, an electrical value of "zero" has been reached in the circuit. It is generally used in situations in which zero is the desired effect. Excludes:ammeter, galvanometer; meter, arbitary scale; and voltmeter."
4.180 inches nominal overall width, 1.930 inches nominal overall height, ac and dc circuit current for which designed, digital display indicator type, 5.100 inches nominal overall length
Product Characteristics
Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.
- Circuit Current For Which Designed
- ac and dc
- Overall Length
- 5.100 inches nominal
- Overall Height
- 1.930 inches nominal
- Overall Width
- 4.180 inches nominal
- Indicator Type
- digital display
- Installation Design
- panel
- Frequency Response Range
- +50.000 to 400.000 hertz
- Meter Depth Behind Mounting Flange
- 4.840 inches nominal
- Meter Body Width Behind Mounting Flange
- 3.920 inches nominal
- Power Source
- external
- Mounting Facility Type And Quantity
- 1 threaded bezel and 2 clamp
- Display Type
- light emitting diode (l.e.d.).
- Display Digit Quantity
- 3-1/2
- Measurement Range
- +0.0 to 5.0 decibels single indicator 2nd range
- Measurement Range
- +0.0 to 50.0 decibels single indicator 3rd range
- Measurement Range
- +0.0 to 500.0 decibels single indicator 4th range
- Measurement Range
- +0.0 to 625.0 decibels single indicator 5th range
- Measurement Range
- +0.0 to 0.5 decibels single indicator 1st range
- Measurement Range
- -0.1999 to 0.1999 volts, dc single indicator 6th range
- Measurement Range
- -0.1999 to 0.1999 volts, root mean square single indicator 11th range
- Measurement Range
- -1.999 to 1.999 volts, dc single indicator 7th range
- Measurement Range
- -1.999 to 1.999 volts, root mean square single indicator 12th range
- Measurement Range
- -19.99 to 19.99 volts, dc single indicator 8th range
- Measurement Range
- -19.99 to 19.99 volts, root mean square single indicator 13th range
- Measurement Range
- -199.9 to 199.9 volts, dc single indicator 9th range
- Measurement Range
- -199.9 to 199.9 volts, root mean square single indicator 14th range
- Measurement Range
- -600.0 to 600.0 volts, dc single indicator 10th range
- Measurement Range
- -600.0 to 600.0 volts, root mean square single indicator 15th range
- Scale Selection Method
- terminal
- Meter Body Height Behind Mounting Flange
- 1.670 inches nominal
- Features Provided
- zero adjuster
- Accuracy Rating
- porm 0.1 pct of reading porm 1 digit single indicator 12th range
- Accuracy Rating
- porm 0.1 pct of reading porm 1 digit single indicator 7th range
- Accuracy Rating
- porm 0.3 pct of reading porm 1 digit single indicator 13th range
- Accuracy Rating
- porm 0.3 pct of reading porm 1 digit single indicator 14th range
- Accuracy Rating
- porm 0.3 pct of reading porm 1 digit single indicator 8th range
- Accuracy Rating
- porm 0.3 pct of reading porm 1 digit single indicator 9th range
- Accuracy Rating
- porm 1.2 pct of reading porm 1 digit single indicator 10th range
- Accuracy Rating
- porm 1.2 pct of reading porm 1 digit single indicator 11th range
- Accuracy Rating
- porm 1.2 pct of reading porm 1 digit single indicator 15th range
- Accuracy Rating
- porm 1.2 pct of reading porm 1 digit single indicator 6th range
- Accuracy Rating
- porm 1.5 db single indicator 1st range
- Accuracy Rating
- porm 1.5 db single indicator 2nd range
- Accuracy Rating
- porm 1.5 db single indicator 3rd range
- Accuracy Rating
- porm 1.5 db single indicator 4th range
- Accuracy Rating
- porm 1.5 db single indicator 5th range
- Display Color
- red single indicator all ranges
- Circuit Attachment Method And Quantity
- 2 connector, plug
- Special Features
- calibration facilities
- Nuclear Hardness Critical Feature
- nonhardened
- Style Designator
- rectangular flush mtg
- Fsc Application Data
- test set,elect. equip.
Related Parts
This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:
| Part Number | Name |
|---|---|
| 10080816-101 | Multimeter |
| AD2033 WITH LENS 8 | Multimeter |
FAQs
Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.
What is the FSCG of the NSN 6625-01-144-7622?
Does the NSN 6625-01-144-7622 have a Schedule B code assigned?
Does NSN 6625-01-144-7622 require demilitarization?
Does NSN 6625-01-144-7622 contain precious materials?
Does NSN 6625-01-144-7622 contain hazardous materials?
When the NSN 6625-01-144-7622 was assigned to the Federal Catalog?
Professional Distribution
Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.
- ITAR Registered
- DDTC Registered
- HAZMAT Certified
- AS9120 Quality Standards
- 100% Quality Inspections
You May Also Like
Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.
Pricing
Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information: