900340-2

View detailed technical data, stock status, and sourcing information for: 900340-2

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part 900340-2 to receive an up to date pricing and availability quote by email.

900340-2
Federal Supply Group
Instruments and Laboratory Equipment
National Stock Number
6625-01-013-8557
Item Name Code
16450
Assigment Date
12/09/1975 (50 years ago)

An electrically operated instrument which has a marked scale or digital readout display, but the unit of measurement is not given. May indicate electrical or nonelectrical effects but is primarily not a current detecting device; therefore, excludes:galvanometer. For instruments whose unit of measurement is not covered by a more specific item, see meter, special scale.

2.030 inches nominal overall length, 0.125 inches nominal mounting hole diameter, 50 single indicator single range scale division quantity, 3000.0 dielectric withstanding voltage in volts, dc circuit current for which designed

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Circuit Current For Which Designed
dc
Dielectric Withstanding Voltage In Volts
3000.0
Overall Length
2.030 inches nominal
Mounting Hole Diameter
0.125 inches nominal
Scale Division Quantity
50 single indicator single range
Overall Diameter
2.695 inches maximum
Mounting Bolt Circle Diameter
2.440 inches nominal
Furnished Items And Quantity
nuts 4; washers 4
Indicator Type
dial w/pointer
Installation Design
panel
Mounting Arrangement Style
three hole/stud bolt circle
Dial Scale Marking Color
black single indicator single range
Accuracy In Percent
-2.0 to 2.0 at full scale single indicator single range
Panel For Which Designed
nonmagnetic
Meter Depth Behind Mounting Flange
1.170 inches nominal
Meter Body Diameter Behind Mounting Flange
2.150 inches nominal
Movement Type
moving coil, permanent magnet
Background Color
white single indicator single range
Pointer Color
black single indicator single range
Power Source
external
Mounting Facility Type And Quantity
3 unthreaded hole
Scale Graduation Type
linear single indicator single range
Measurement Range
+0.0 to 1.0 milliamperes, dc single indicator single range
Circuit Construction Type
nonelectronic
Scale Selection Method
terminal
Features Provided
zero adjuster
Movement Suspension Method
jewel pivot base
Circuit Attachment Method And Quantity
2 solder lug and 2 threaded stud
Material
plastic
Nuclear Hardness Critical Feature
nonhardened
Special Test Features
complies with mil-m-10304
Style Designator
round flush mtg
Fsc Application Data
test set,elect. equip.

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
621-16677 Ammeter
900340-2 Ammeter

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 6625-01-013-8557?
The FSCG of the NSN 6625-01-013-8557 is 6625
Does the NSN 6625-01-013-8557 have a Schedule B code assigned?
Yes, the Schedule B code is 9030908030
Does NSN 6625-01-013-8557 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 6625-01-013-8557 contain precious materials?
Item does not contain precious metal.
Does NSN 6625-01-013-8557 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 6625-01-013-8557 was assigned to the Federal Catalog?
It was assigned 50 years ago, on Tue, Dec 9, 1975

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

1792080-501
5950-00-420-5744
Radio Frequency Transformer
1792082-501
5950-00-420-1605
Radio Frequency Transformer
1792085-501
5950-00-234-7544
Radio Frequency Transformer
1792086-501
5950-00-420-1588
Radio Frequency Transformer
1792087-504
5950-00-420-1592
Radio Frequency Coil
1792087-508
5950-00-420-1586
Radio Frequency Coil
1792087-509
5950-00-420-1585
Radio Frequency Coil
1792087-510
5950-00-420-1591
Radio Frequency Coil
1792087-511
5950-00-435-8430
Radio Frequency Coil
1792087-514
5950-00-435-8445
Radio Frequency Coil
1792087-515
5950-00-435-8431
Radio Frequency Coil
1792087-517
5950-00-420-1587
Radio Frequency Coil
179209
2810-00-396-4116
Plate
179209-1
7010-01-601-1969
D Installation and Equipment Kit
179209-2
7010-01-602-4164
D Installation and Equipment Kit