DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 6625-00-983-8794 to receive an up to date pricing and availability quote by email.

6625-00-983-8794
Federal Supply Group
Instruments and Laboratory Equipment
National Stock Number
6625-00-983-8794
Item Name Code
00794
Assigment Date
01/01/1962 (64 years ago)

4.000 inches nominal center to center distance between mounting facilities parallel to length, 4.156 inches nominal overall height, 2.297 inches nominal overall length, ac circuit current for which designed, 3.562 inches nominal center to center distance between mounting facilities parallel to width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Circuit Current For Which Designed
ac
Overall Length
2.297 inches nominal
Center To Center Distance Between Mounting Facilities Parallel To Length
4.000 inches nominal
Center To Center Distance Between Mounting Facilities Parallel To Width
3.562 inches nominal
Overall Height
4.156 inches nominal
Overall Width
4.656 inches nominal
Scale Division Quantity
20 single indicator 2nd range
Scale Division Quantity
35 single indicator 3rd range
Mounting Stud Length
0.953 inches nominal
Furnished Items And Quantity
nut 4
Indicator Type
dial w/pointer
Installation Design
panel
Mounting Arrangement Style
four hole/stud rectangular/square
Sensitivity Rating
200.0 microamperes
Dial Scale Marking Color
black single indicator 2nd range
Dial Scale Marking Color
black single indicator 3rd range
Dial Scale Marking Color
red single indicator 1st range
Accuracy In Percent
-2.0 to 2.0 at full scale single indicator all ranges
Meter Depth Behind Mounting Flange
0.953 inches nominal
Meter Body Diameter Behind Mounting Flange
2.734 inches nominal
Background Color
white single indicator all ranges
Pointer Color
red single indicator all ranges
Power Source
external
Mounting Facility Type And Quantity
4 threaded stud
Scale Graduation Type
nonlinear single indicator 1st range
Scale Graduation Type
linear single indicator 2nd range
Scale Graduation Type
linear single indicator 3rd range
Measurement Range
+1.0 to 3.0 volts, root mean square single indicator 2nd range
Measurement Range
+0.0 to 10.0 decibels single indicator 1st range
Measurement Range
+3.0 to 10.0 volts, root mean square single indicator 3rd range
Mounting Stud Diameter
0.138 inches nominal
Scale Selection Method
terminal
Features Provided
knife edge pointer and zero adjuster
Circuit Attachment Method And Quantity
2 threaded stud
Special Features
1400 ohms porm 10 pct int meter res
Material
plastic
Nuclear Hardness Critical Feature
nonhardened
Style Designator
rectangular flush mtg
Fsc Application Data
test set,elect. equip.

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
6625-00-889-1567 No Name Available 01/01/1988

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 6625-00-983-8794?
The FSCG of the NSN 6625-00-983-8794 is 6625
Does the NSN 6625-00-983-8794 have a Schedule B code assigned?
Yes, the Schedule B code is 9030908030
Does NSN 6625-00-983-8794 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 6625-00-983-8794 contain precious materials?
Item does not contain precious metal.
Does NSN 6625-00-983-8794 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 6625-00-983-8794 was assigned to the Federal Catalog?
It was assigned 64 years ago, on Mon, Jan 1, 1962

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

613707A-688-Z
5840-01-356-5278
Clamp
613708-1
5930-00-815-0104
Push Switch
613709-3
5930-00-821-5377
Rotary Switch
61370HA
2805-00-275-3052
Piston Pin
61371
5305-01-079-0302
Machine Screw
61371-1
5895-01-676-8778
Receiver-Transmitter Subassembly
61371-17
5910-00-414-7868
Glass Dielectric Fixed Capacitor
6137101
1280-00-313-9314
Indicator Dial Pan
613710A-584-SL
5342-01-482-4985
Grooved Clamp Coupling
6137117
1280-00-560-9821
Magneti Damper Assy
6137118
1280-00-560-9820
Damper Assy
613713
6930-00-670-3586
Drum-Resistance Assembly
6137145
4920-00-628-4832
Flight Control System Test Set
613715-1
5945-00-822-3858
Electromagnetic Relay
613715-101
5945-00-106-2863
Electromagnetic Relay