6625-00-581-2294

Find complete technical information, availability, and procurement data for: 6625-00-581-2294

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 6625-00-581-2294 to receive an up to date pricing and availability quote by email.

6625-00-581-2294
Federal Supply Group
Instruments and Laboratory Equipment
National Stock Number
6625-00-581-2294
Item Name Code
16450
Assigment Date
01/01/1963 (63 years ago)

An instrument which measures electric current and is calibrated and marked in amperes or any multiple and/or submultiple thereof. The value may be expressed by means of a pointer and calibrated dial or a digital readout display. For current detecting type of devices, see galvanometer.

0.125 inches nominal mounting hole diameter, ac circuit current for which designed, 2.650 inches maximum overall length, 30 single indicator single range scale division quantity, 3000.0 dielectric withstanding voltage in volts

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Circuit Current For Which Designed
ac
Dielectric Withstanding Voltage In Volts
3000.0
Overall Length
2.650 inches maximum
Mounting Hole Diameter
0.125 inches nominal
Scale Division Quantity
30 single indicator single range
Frequency Rating
400.0 hertz nominal
Overall Diameter
2.695 inches maximum
Environmental Protection
airtight and dust resistant and fungus resistant and heat resistant and humidity resistant and shock resistant and vibration resistant and water resistant
Mounting Bolt Circle Diameter
2.440 inches nominal
Furnished Items And Quantity
nut 7; lockwasher 5; seal 1
Indicator Type
dial w/pointer
Installation Design
panel
Mounting Arrangement Style
three hole/stud bolt circle
Frequency Response Range
+360.000 to 440.000 hertz
Sensitivity Rating
2.0 volt-amperes
Dial Scale Marking Color
black single indicator single range
Accuracy In Percent
-2.0 to 2.0 at full scale single indicator single range
Panel For Which Designed
magnetic
Meter Depth Behind Mounting Flange
1.600 inches maximum
Meter Body Diameter Behind Mounting Flange
2.210 inches maximum
Movement Type
moving iron vane
Background Color
white single indicator single range
Pointer Color
black single indicator single range
Power Source
external
Mounting Facility Type And Quantity
3 screw and 3 unthreaded hole
Scale Graduation Type
linear single indicator single range
Measurement Range
+0.0 to 300.0 milliamperes, ac single indicator single range
Circuit Construction Type
nonelectronic
Scale Selection Method
terminal
Features Provided
magnetic shield and zero adjuster
Movement Suspension Method
jewel pivot base
Circuit Attachment Method And Quantity
2 solder lug and 2 threaded stud
Special Features
ruggedized
Special Markings
on back,sealed do not open
Material
steel
Nuclear Hardness Critical Feature
nonhardened
Surface Treatment
paint
Special Test Features
complies with mil-m-10304
Style Designator
round flush mtg
Test Data Document
"81349-mil-10304 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Specification/Standard Data
81349-mil-m-10304/7 government specification
Fsc Application Data
test set,elect. equip.

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
6625-00-425-6827 No Name Available 11/14/1984

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
MR26W300AFMAR Ammeter

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 6625-00-581-2294?
The FSCG of the NSN 6625-00-581-2294 is 6625
Does the NSN 6625-00-581-2294 have a Schedule B code assigned?
Yes, the Schedule B code is 9030908030
Does NSN 6625-00-581-2294 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 6625-00-581-2294 contain precious materials?
Item does not contain precious metal.
Does NSN 6625-00-581-2294 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 6625-00-581-2294 was assigned to the Federal Catalog?
It was assigned 63 years ago, on Tue, Jan 1, 1963

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

DUCTILEND 80 0.156
3439-01-043-0241
Welding Electrode
DUCTILEND 80 0.187
3439-01-038-3773
Welding Electrode
DUCTILEND 80 0.187 10LB
3439-00-482-4842
Welding Electrode
DUCTILEND 85 0.125
3439-00-853-2716
Welding Electrode
DUCTILEND 85 0.156
3439-00-853-2718
Welding Electrode
DUCTITE 320-9
6850-00-281-2337
Chemical Sealer
DUCTSEALER 101
8030-00-933-7084
Sealing Compound
DUCTSEALER 102
8030-00-933-7084
Sealing Compound
DUCTTAPEALUMINUM
5640-00-409-4265
Duct Tape
DUCTURN BLADE
4520-00-510-3258
Turning Vane Blade
DUCTURNSIDEPIECE
4130-00-797-3483
Ducturn Sidepiece
DUDB202E15B
4820-01-413-1115
Safety Relief Valve
DUDLEY-4004
5998-01-549-4202
Electronic Components Assembly
DUELADAPTER
5935-01-688-3922
Electrical Plug Connector
DUET
6350-01-398-6099
Light Intensity Detector