6625-00-478-3092

Find complete technical information, availability, and procurement data for: 6625-00-478-3092

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 6625-00-478-3092 to receive an up to date pricing and availability quote by email.

6625-00-478-3092
Federal Supply Group
Instruments and Laboratory Equipment
National Stock Number
6625-00-478-3092
Item Name Code
16450
Assigment Date
06/12/1974 (52 years ago)

"an electrically operated instrument having a zero point on its scale (usually located in the center thereof). It may not indicate units of electrical measurement. The value may be expressed by means of a pointer and calibrated dial or a digital readout display. When the indication shows zero, an electrical value of "zero" has been reached in the circuit. It is generally used in situations in which zero is the desired effect. Excludes:ammeter, galvanometer; meter, arbitary scale; and voltmeter."

1.800 inches nominal overall height, 1.312 inches nominal center to center distance between mounting facilities parallel to length, 1.312 inches nominal center to center distance between mounting facilities parallel to width, 1.625 inches maximum overall length, dc circuit current for which designed

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Circuit Current For Which Designed
dc
Overall Length
1.625 inches maximum
Center To Center Distance Between Mounting Facilities Parallel To Length
1.312 inches nominal
Center To Center Distance Between Mounting Facilities Parallel To Width
1.312 inches nominal
Overall Height
1.800 inches nominal
Overall Width
1.800 inches nominal
Scale Division Quantity
50 single indicator single range
Mounting Stud Length
0.375 inches maximum
Indicator Type
dial w/pointer
Installation Design
panel
Mounting Arrangement Style
four hole/stud rectangular/square
Dial Scale Marking Color
black single indicator single range
Accuracy In Percent
-3.0 to 3.0 at full scale single indicator single range
Panel For Which Designed
nonmagnetic
Meter Depth Behind Mounting Flange
1.250 inches maximum
Meter Body Diameter Behind Mounting Flange
1.510 inches maximum
Movement Type
moving iron vane
Background Color
white single indicator single range
Pointer Color
black single indicator single range
Power Source
external
Mounting Facility Type And Quantity
4 threaded stud
Scale Graduation Type
linear single indicator single range
Measurement Range
+0.0 to 50.0 microamperes, dc single indicator single range
Circuit Construction Type
nonelectronic
Mounting Stud Diameter
0.125 inches nominal
Scale Selection Method
terminal
Features Provided
zero adjuster
Movement Suspension Method
jewel pivot base
Circuit Attachment Method And Quantity
2 solder lug
Nuclear Hardness Critical Feature
nonhardened
Style Designator
rectangular flush mtg
Fsc Application Data
test set,elect. equip.

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
4010438-0701 Ammeter

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 6625-00-478-3092?
The FSCG of the NSN 6625-00-478-3092 is 6625
Does the NSN 6625-00-478-3092 have a Schedule B code assigned?
Yes, the Schedule B code is 9030908030
Does NSN 6625-00-478-3092 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 6625-00-478-3092 contain precious materials?
Item does not contain precious metal.
Does NSN 6625-00-478-3092 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 6625-00-478-3092 was assigned to the Federal Catalog?
It was assigned 52 years ago, on Wed, Jun 12, 1974

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

9-230075
5930-00-822-4452
Switch Assembly
9-230077
5930-01-046-9021
Pressure Switch
9-230092
5930-00-910-1091
Pressure D Actuator
9-230094
5930-00-015-1784
Pressure Switch
9-230102
5930-00-840-5776
Switch Assembly
9-230118
5930-00-247-1472
Pressure Switch
9-2307
5950-00-867-0949
Power Transformer
9 2307 02 003
5310-01-424-1828
Lock Washer
9 2307 10 100
5998-01-423-4826
Circuit Card Assembly
9-2307-10-101
5998-01-534-1435
Circuit Card Assembly
9 2307 10 102
5998-01-450-7755
Circuit Card Assembly
9 2307 11 100
5998-01-416-9323
Circuit Card Assembly
9-2307-11-101
5998-01-534-1429
Circuit Card Assembly
9 2307 11 102
5998-01-450-7757
Circuit Card Assembly
9-2307-1341
4820-01-714-8320
Fluid Pressure Regulating Valve