6625-00-444-9773

Find complete technical information, availability, and procurement data for: 6625-00-444-9773

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 6625-00-444-9773 to receive an up to date pricing and availability quote by email.

6625-00-444-9773
Federal Supply Group
Instruments and Laboratory Equipment
National Stock Number
6625-00-444-9773
Item Name Code
16450
Assigment Date
01/01/1961 (65 years ago)

An instrument which measures electric current and is calibrated and marked in amperes or any multiple and/or submultiple thereof. The value may be expressed by means of a pointer and calibrated dial or a digital readout display. For current detecting type of devices, see galvanometer.

dc circuit current for which designed, 1.312 inches nominal center to center distance between mounting facilities parallel to width, 1.750 inches nominal overall height, 1.250 inches nominal overall length, 1.312 inches nominal center to center distance between mounting facilities parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Circuit Current For Which Designed
dc
Overall Length
1.250 inches nominal
Center To Center Distance Between Mounting Facilities Parallel To Length
1.312 inches nominal
Center To Center Distance Between Mounting Facilities Parallel To Width
1.312 inches nominal
Overall Height
1.750 inches nominal
Overall Width
1.750 inches nominal
Mounting Hole Diameter
0.125 inches nominal
Scale Division Quantity
20 single indicator single range
Indicator Type
dial w/pointer
Installation Design
panel
Mounting Arrangement Style
four hole/stud rectangular/square
Sensitivity Rating
100.0 millivolts
Dial Scale Marking Color
black single indicator single range
Accuracy In Percent
-3.0 to 3.0 at full scale single indicator single range
Panel For Which Designed
nonmagnetic
Meter Depth Behind Mounting Flange
0.875 inches nominal
Meter Body Diameter Behind Mounting Flange
1.510 inches nominal
Movement Type
moving iron vane
Background Color
white single indicator single range
Pointer Color
black single indicator single range
Power Source
external
Mounting Facility Type And Quantity
4 unthreaded hole
Scale Graduation Type
linear single indicator single range
Measurement Range
+0.0 to 10.0 milliamperes, dc single indicator single range
Circuit Construction Type
nonelectronic
Scale Selection Method
terminal
Features Provided
zero adjuster
Movement Suspension Method
jewel pivot base
Circuit Attachment Method And Quantity
2 solder lug
Special Features
ruggedized
Nuclear Hardness Critical Feature
nonhardened
Style Designator
rectangular flush mtg
Fsc Application Data
test set,elect. equip.

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
4400D0750-4 Ammeter

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 6625-00-444-9773?
The FSCG of the NSN 6625-00-444-9773 is 6625
Does the NSN 6625-00-444-9773 have a Schedule B code assigned?
Yes, the Schedule B code is 9030908030
Does NSN 6625-00-444-9773 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 6625-00-444-9773 contain precious materials?
Item does not contain precious metal.
Does NSN 6625-00-444-9773 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 6625-00-444-9773 was assigned to the Federal Catalog?
It was assigned 65 years ago, on Sun, Jan 1, 1961

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

3402014-1
1560-01-535-6467
Fuselage Parts Kit
3402014-2
1560-00-993-2079
Beam Repair Kit
3402014-3
1560-01-536-8088
Fuselage Parts Kit
3402014-4
1560-00-885-1802
Aircraft Beam Parts Kit
34020145SE
7025-01-626-3627
Display Unit
3402026
5330-01-190-0309
Packing Retainer
3402027-1
5120-01-016-6832
Torque Adapter Aasy
3402035
5905-00-780-8763
Resistor,fixed,wire Wound,induct
3402037-79
5133-00-115-9727
Bracket Core Drill
3402038
5305-01-215-1337
Machine Screw
34020390-001
5950-01-076-6986
Power Transformer
3402043
5340-01-527-3468
Angle Bracket
3402044-1
6695-01-074-9787
Main Lan Track Gage
3402044-23
1620-01-234-4529
Indicator Assembly,
3402045-1
5120-01-344-1510
Torque Wrench Adapter