6625-00-078-6788

Find complete technical information, availability, and procurement data for: 6625-00-078-6788

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 6625-00-078-6788 to receive an up to date pricing and availability quote by email.

6625-00-078-6788
Federal Supply Group
Instruments and Laboratory Equipment
National Stock Number
6625-00-078-6788
Item Name Code
16450
Assigment Date
01/01/1961 (65 years ago)

An instrument which measures electric current and is calibrated and marked in amperes or any multiple and/or submultiple thereof. The value may be expressed by means of a pointer and calibrated dial or a digital readout display. For current detecting type of devices, see galvanometer.

dc circuit current for which designed, 2.130 inches maximum overall length, 25 single indicator all ranges scale division quantity, 0.500 inches nominal mounting stud length, 3000.0 dielectric withstanding voltage in volts

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Circuit Current For Which Designed
dc
Dielectric Withstanding Voltage In Volts
3000.0
Overall Length
2.130 inches maximum
Scale Division Quantity
25 single indicator all ranges
Mounting Stud Length
0.500 inches nominal
Overall Diameter
2.695 inches nominal
Mounting Bolt Circle Diameter
2.440 inches nominal
Furnished Items And Quantity
washers 3,nuts 3
Indicator Type
dial w/pointer
Installation Design
panel
Mounting Arrangement Style
three hole/stud bolt circle
Sensitivity Rating
100.0 millivolts
Dial Scale Marking Color
black single indicator all ranges
Accuracy In Percent
-2.0 to 2.0 at full scale single indicator all ranges
Panel For Which Designed
magnetic
Meter Depth Behind Mounting Flange
1.500 inches maximum
Meter Body Diameter Behind Mounting Flange
2.210 inches maximum
Movement Type
moving coil, permanent magnet
Background Color
white single indicator all ranges
Pointer Color
black single indicator all ranges
Power Source
external
Mounting Facility Type And Quantity
3 threaded stud
Scale Graduation Type
linear single indicator all ranges
Measurement Range
+0.0 to 25.0 milliamperes, dc single indicator 1st range
Measurement Range
+0.0 to 250.0 milliamperes, dc single indicator 2nd range
Circuit Construction Type
nonelectronic
Mounting Stud Diameter
0.125 inches nominal
Scale Selection Method
terminal
Features Provided
magnetic shield and zero adjuster
Movement Suspension Method
jewel pivot base
Circuit Attachment Method And Quantity
2 solderless lug
Special Features
ruggedized
Nuclear Hardness Critical Feature
nonhardened
Style Designator
round flush mtg
Fsc Application Data
test set,elect. equip.

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
330C930H13 Ammeter

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 6625-00-078-6788?
The FSCG of the NSN 6625-00-078-6788 is 6625
Does the NSN 6625-00-078-6788 have a Schedule B code assigned?
Yes, the Schedule B code is 9030908030
Does NSN 6625-00-078-6788 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 6625-00-078-6788 contain precious materials?
Item does not contain precious metal.
Does NSN 6625-00-078-6788 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 6625-00-078-6788 was assigned to the Federal Catalog?
It was assigned 65 years ago, on Sun, Jan 1, 1961

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

190-92-469
5820-00-991-3409
R0t0r Assembly
190-92-470
5910-00-732-2118
Capacitor Rotor
190-92-490
5340-00-760-8936
Spring Holder
190-92-492
5360-00-760-8938
Helical Spring
190-92-497
5360-00-760-8943
Helical Spring
190-92-498
5360-00-760-8944
Extension Helical Spring
190-92-502
5820-00-760-8947
Stator Assembly
190-92-503
5895-00-987-5447
Receiver-Transmitter Subassembly
190-92-504
5930-00-981-3420
Switch Actuator Arm
190-92-505
5950-00-987-3489
Coil Assembly
190-92-506
5930-00-991-8735
Rotary Switch Section
190-92-507
5820-00-760-8952
Switching Device
190-92-525
5930-00-987-3540
Rotary Switch
190-92-541
5950-00-984-1513
Radio Frequency Transformer
190-92-545
5950-00-991-3484
Radio Frequency Coil Assembly