1. Home /
  2. Catalog /
  3. Coils and Transformers /
  4. 5950-01-384-1713

5950-01-384-1713

Find complete technical information, availability, and procurement data for: 5950-01-384-1713

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5950-01-384-1713 to receive an up to date pricing and availability quote by email.

5950-01-384-1713
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5950 Coils and Transformers
National Stock Number
5950-01-384-1713
Item Name Code
32496
Assigment Date
12/09/1993 (32 years ago)

An item consisting of a partial turn as one or more turns of wire or other conductive material which constitutes one continuous untapped winding. It may be wound or formed in other than a circular manner and may be self-supporting, requiring no coil form. It is specifically designed to furnish inductive reactance in a circuit carrying radio frequency current ranging from 20 kilohertz (kilocycles) and above. It may include tuning devices, integral resistors and capacitors; however, excludes:filter (as modified). The coil has only two electrical terminals. For items having tapped winding or more than one winding - see transformer, radio frequency. For coils wound on resistors, which are designed to be inserted in the circuit of a radio frequency stage to suppress high frequency parasitic oscillations, see suppressor, parasitic.

single phase to single phase single component input-output phase relationship, not established reliability indicator, internal shield brought out to terminal single component winding shielding method, 40.0 kilohertz nominal single component frequency rating, 400.0 volt-ampere single component maximum transformer power rating

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Reliability Indicator
not established
Frequency Rating
40.0 kilohertz nominal single component
Input-Output Phase Relationship
single phase to single phase single component
Maximum Transformer Power Rating
400.0 volt-ampere single component
Winding Shielding Method
internal shield brought out to terminal single component
Body Length
2.075 inches nominal
Body Width
1.310 inches nominal
Body Height
1.503 inches nominal
Inclosure Type
fully inclosed
Mounting Method
terminal single group
Winding Function And Quantity
1 primary and 3 secondary single component
Winding Operating Current
4.0 amperes ac nominal single component single primary
Winding Power Rating
400.0 volts-amperes single component single primary
Winding Operating Voltage
100.00 ac volts nominal single component single primary
Terminal Type And Quantity
5 pin and 3 wire lead

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
050-005195-001 Power Transformer

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5950-01-384-1713?
The FSCG of the NSN 5950-01-384-1713 is 5950
Does the NSN 5950-01-384-1713 have a Schedule B code assigned?
Yes, the Schedule B code is 8504314065
Does NSN 5950-01-384-1713 require demilitarization?
"commerce control list items (ccli) - mut to the point of scrap required outside the united states. Inside the united states, mut is required when the demil integrity code (ic) is "3" and mut is not required when the demic is "6" (note 8)"
Does NSN 5950-01-384-1713 contain precious materials?
Item does not contain precious metal.
Does NSN 5950-01-384-1713 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5950-01-384-1713 was assigned to the Federal Catalog?
It was assigned 32 years ago, on Thu, Dec 9, 1993

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

MS21341A
6645-01-622-6161
Time Totalizing Meter
MS21341A-03
6645-01-262-2269
Time Totalizing Meter
MS21341A-04
6645-01-563-0441
Time Totalizing Meter
MS21341A-05
6645-01-333-1713
Time Totalizing Meter
MS21341A-06
6645-01-352-5426
Time Totalizing Meter
MS21341A-07
6645-01-321-5510
Time Totalizing Meter
MS21341A-08
6645-01-379-7251
Time Totalizing Meter
MS21341A-09
6645-01-290-0393
Time Totalizing Meter
MS21341A-10
6645-01-550-4586
Time Totalizing Meter
MS21341A-11
6645-01-344-7898
Time Totalizing Meter
MS21341A-12
6645-01-359-5769
Time Totalizing Meter
MS21341A-13
6645-01-338-8885
Time Totalizing Meter
MS21341A-14
6645-01-357-9096
Time Totalizing Meter
MS21341A-17
6645-01-301-8334
Time Totalizing Meter
MS21341A-21
6645-01-420-6804
Time Totalizing Meter