1. Home /
  2. Catalog /
  3. Coils and Transformers /
  4. 5950-01-074-3391

5950-01-074-3391

Find complete technical information, availability, and procurement data for: 5950-01-074-3391

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5950-01-074-3391 to receive an up to date pricing and availability quote by email.

5950-01-074-3391
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5950 Coils and Transformers
National Stock Number
5950-01-074-3391
Item Name Code
32496
Assigment Date
03/30/1979 (47 years ago)

A definite continuous length of cable,special purpose,electrical, having one or more ends processed or terminated in fittings which provide for connectionn to other items. For items which the rated working is 300 volts or more, see: cable assembly,power,electrical. Excludes items having branches or forks. Excludes: lead,test and cable and conduit assembly,electrical.

400.0 hertz nominal single component frequency rating, 2.400 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to width, not established reliability indicator, 4.000 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to length, three phase to three phase single component input-output phase relationship

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Reliability Indicator
not established
Center To Center Distance Between Mounting Facilities Parallel To Length
4.000 inches nominal single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width
2.400 inches nominal single mounting facility single center group
Frequency Rating
400.0 hertz nominal single component
Input-Output Phase Relationship
three phase to three phase single component
Body Length
4.650 inches maximum
Body Width
3.120 inches maximum
Body Height
2.900 inches maximum
Inclosure Type
fully inclosed
Mounting Facility Quantity
4 single group
Mounting Method
threaded hole single group
Winding Function And Quantity
1 primary and 2 secondary single component
Thread Quantity Per Inch
32 single group
Nominal Thread Size
0.138 inches single group
Winding Operating Current
6.0 amperes ac maximum single component single primary
Winding Operating Current
40.0 amperes ac maximum single component 3rd secondary
Winding Operating Voltage
115.00 ac volts nominal single component single primary
Winding Operating Voltage
22.10 ac volts nominal single component all secondary
Thread Series Designator
unef single group
Terminal Type And Quantity
10 tab, solder lug

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
5-598-03 Power Transformer

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5950-01-074-3391?
The FSCG of the NSN 5950-01-074-3391 is 5950
Does NSN 5950-01-074-3391 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5950-01-074-3391 contain precious materials?
Precious metal content is unknown
Does NSN 5950-01-074-3391 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5950-01-074-3391 was assigned to the Federal Catalog?
It was assigned 47 years ago, on Fri, Mar 30, 1979

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

M24716TY1CLC/4.125X3.375X1/8TH
5330-01-500-6024
Gasket
M24716TY1CLC/5X4.25X1/8THK
5330-01-500-6028
Gasket
M24716TY2,CLA,0.500NPS150PSICRES
5330-01-678-0137
Spiral Wound Gasket
M24716TY2 CLA .250NPI 600PSI
5330-01-338-7816
Spiral Wound Gasket
M24716TY2,CLA,5090NPS,150PSICRES
5330-01-678-0137
Spiral Wound Gasket
M24716TY2 CLB 1.25NPS 150PSI
5330-01-338-7797
Spiral Wound Gasket
M24716TY2 CLB 10.000NPS 150IPS
5330-01-338-7798
Spiral Wound Gasket
M24716TY2C1.500NPS150PSI
5330-01-338-7854
Spiral Wound Gasket
M24716TY2CL22.00NPS150PSICRPL
5330-01-336-9485
Spiral Wound Gasket
M24716TY2CL3.00NPS600PSINICU
5330-01-500-6058
Spiral Wound Gasket
M24716TY2CL4.000NPS 300PSI
5330-01-338-7794
Spiral Wound Gasket
M24716TY2CLA 2.000NPS 2500PSI
5330-01-338-7815
Spiral Wound Gasket
M24716TY2CLA .250NPS 150PSI
5330-01-388-2138
Spiral Wound Gasket
M24716TY2CLA.500IPS150PSI
5330-01-338-7823
Spiral Wound Gasket
M24716TY2CLA.500NPS 2500PSI
5330-01-338-7799
Spiral Wound Gasket