1. Home /
  2. Catalog /
  3. Coils and Transformers /
  4. 5950-00-900-7040

5950-00-900-7040

Find complete technical information, availability, and procurement data for: 5950-00-900-7040

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5950-00-900-7040 to receive an up to date pricing and availability quote by email.

5950-00-900-7040
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5950 Coils and Transformers
National Stock Number
5950-00-900-7040
Item Name Code
32496
Assigment Date
04/19/1968 (58 years ago)

1.250 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to width, 60.0 hertz nominal single component frequency rating, 2.813 inches nominal overall length, not established reliability indicator, 1.375 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Reliability Indicator
not established
Overall Length
2.813 inches nominal
Center To Center Distance Between Mounting Facilities Parallel To Length
1.375 inches nominal single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width
1.250 inches nominal single mounting facility single center group
Frequency Rating
60.0 hertz nominal single component
Input-Output Phase Relationship
single phase to single phase single component
Winding Shielding Method
internal shield grounded to core single component
Body Length
2.438 inches nominal
Body Width
1.812 inches nominal
Body Height
1.938 inches nominal
Maximum Operating Temp
70.0 celsius
Inclosure Type
hermetically sealed
Mounting Facility Quantity
4 single group
Mounting Method
threaded stud single group
Winding Function And Quantity
1 primary and 1 secondary single component
Thread Quantity Per Inch
32 single group
Nominal Thread Size
0.138 inches single group
Winding Operating Current
10.0 milliamperes ac maximum single component single secondary
Winding Operating Voltage
115.00 ac volts nominal single component single secondary
Winding Operating Voltage
440.00 ac volts nominal single component single primary
Test Data Document
10001-25153891 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
Thread Series Designator
unc single group
Terminal Type And Quantity
4 tab, solder lug

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5950-00-922-4893 No Name Available 03/21/1973

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
2515389-1 Power Transformer

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5950-00-900-7040?
The FSCG of the NSN 5950-00-900-7040 is 5950
Does NSN 5950-00-900-7040 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5950-00-900-7040 contain precious materials?
Item does not contain precious metal.
Does NSN 5950-00-900-7040 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5950-00-900-7040 was assigned to the Federal Catalog?
It was assigned 58 years ago, on Fri, Apr 19, 1968

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

P610-B1V12
5945-01-641-2459
Electrical Solenoid
P610001603
5940-00-900-3755
Stud Terminal
P610003001
5940-00-106-2630
Stud Terminal
P610003301
5940-00-259-9127
Stud Terminal
P610005901
5940-01-281-4712
Stud Terminal
P610035A
5905-00-841-6988
Wire Wound Fixed Resistor
P610051
4720-00-833-0868
Nonmetallic Tubing
P610053
4720-00-833-0867
Nonmetallic Tubing
P6100NSC
5920-01-384-8605
Surge Protector
P6101A
6625-01-459-7526
Test Probe-Lead Assembly
P6101A-001
6625-00-165-5867
Test Probe-Lead Assembly
P6101A OPT 01
6625-00-165-5867
Test Probe-Lead Assembly
P6101A OPT 03
6625-00-477-1384
Test Lead
P6101B
6625-00-907-8358
Test Lead
P6101B OPT 01
6625-00-165-5867
Test Probe-Lead Assembly