Find complete technical information, availability, and procurement data for: 5950-00-842-4430

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5950-00-842-4430 to receive an up to date pricing and availability quote by email.

5950-00-842-4430
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5950 Coils and Transformers
National Stock Number
5950-00-842-4430
Item Name Code
00724
Assigment Date
01/01/1962 (64 years ago)

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes:transformer (1), pulse.

not established reliability indicator, 8.125 inches nominal overall height, 4.875 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to width, 6.000 inches nominal overall length, 5.000 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Reliability Indicator
not established
Overall Length
6.000 inches nominal
Center To Center Distance Between Mounting Facilities Parallel To Length
5.000 inches nominal single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width
4.875 inches nominal single mounting facility single center group
Overall Height
8.125 inches nominal
Overall Width
5.875 inches nominal
Inductance Type
fixed
Inductance Rating
5.00 henry nominal single component single winding
Body Length
6.000 inches nominal
Body Width
5.875 inches nominal
Body Height
6.625 inches nominal
Winding Quantity
1 single component
Inclosure Type
hermetically sealed
Mounting Facility Quantity
4 single group
Mounting Method
threaded stud single group
Rating Method
electrical single component single winding
Thread Quantity Per Inch
20 single group
Nominal Thread Size
0.250 inches single group
Winding Operating Current
1.0 amperes dc maximum single component single winding
Dc Resistance Rating In Ohms
20.000 single component single winding
Thread Series Designator
unc single group
Terminal Type And Quantity
2 standoff, solder lug

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5950-00-842-4430?
The FSCG of the NSN 5950-00-842-4430 is 5950
Does the NSN 5950-00-842-4430 have a Schedule B code assigned?
Yes, the Schedule B code is 8504900020
Does NSN 5950-00-842-4430 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5950-00-842-4430 contain precious materials?
Precious metal content is unknown
Does NSN 5950-00-842-4430 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5950-00-842-4430 was assigned to the Federal Catalog?
It was assigned 64 years ago, on Mon, Jan 1, 1962

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

1548953-205
5330-01-311-8592
Plain Seal
1548959-1
5950-00-046-5484
Power Transformer
1548959-2
5950-00-046-5529
Power Transformer
1548959-3
5950-00-046-5567
Power Transformer
1548959-4
5950-01-216-7331
Power Transformer
1548959-6
5950-01-086-6288
Power Transformer
154896
5865-00-401-4916
Hydraulic S Fitting
154897
5310-00-891-1631
Flat Washer
154899
2090-01-623-7045
Un Launch and Recovery Subsystem
1548A16
5340-01-132-4744
Hinged Hasp
1548C
5310-01-285-0542
Round Plain Nut
1548C0000TM REV A V7 FIND NO 1
4130-01-602-0216
Duct Type Air Cooling Coil
1548C0000TM REV A V7 FIND NO 10
5845-01-602-1868
Flow Transducer
1548C0000TM REV A V8 FIND NO 1
4130-01-602-0194
Duct Type Air Cooling Coil
1548C0000TM REV A V8 FIND NO 10
5845-01-602-1856
Flow Transducer