1. Home /
  2. Catalog /
  3. Coils and Transformers /
  4. 5950-00-488-9901

5950-00-488-9901

Find complete technical information, availability, and procurement data for: 5950-00-488-9901

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5950-00-488-9901 to receive an up to date pricing and availability quote by email.

5950-00-488-9901
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5950 Coils and Transformers
National Stock Number
5950-00-488-9901
Item Name Code
32496
Assigment Date
05/18/1970 (56 years ago)

A coil or coils usually constructed with cores having low magnetic reluctance, whose primary purpose is to furnish an inductive impedance in power or audio frequency circuit ranging from zero to 20 kilohertz (kilocycles). Includes audio frequency and power filter chokes, audio reactors and swinging chokes. Does not include transformers or coils used above audio frequency range. Excludes:saturable reactor. For reactors with air cores, see coil (as modified).

not established reliability indicator, 50.0 hertz minimum and 1.0 kilohertz maximum single component frequency rating, 3.000 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to width, 2.930 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to length, 0.234 inches nominal single group mounting slot width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Reliability Indicator
not established
Center To Center Distance Between Mounting Facilities Parallel To Length
2.930 inches nominal single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width
3.000 inches nominal single mounting facility single center group
Mounting Slot Width
0.234 inches nominal single group
Frequency Rating
50.0 hertz minimum and 1.0 kilohertz maximum single component
Input-Output Phase Relationship
single phase to single phase single component
Body Length
5.620 inches nominal
Body Width
3.500 inches nominal
Body Height
4.250 inches nominal
Inclosure Type
fully inclosed
Mounting Facility Quantity
4 single group
Mounting Method
slot single group
Winding Function And Quantity
2 primary and 5 secondary single component
Winding Operating Current
1.8 amperes dc maximum single component 3rd secondary
Winding Operating Current
325.0 milliamperes dc maximum single component 2nd secondary
Winding Operating Current
340.0 milliamperes dc maximum single component 4th secondary
Winding Operating Current
375.0 milliamperes dc maximum single component 1st secondary
Winding Operating Voltage
15.00 dc volts nominal single component 3rd secondary
Winding Operating Voltage
17.00 dc volts nominal single component 2nd secondary
Winding Operating Voltage
300.00 dc volts nominal single component 4th secondary
Winding Operating Voltage
22.00 dc volts nominal single component 1st secondary
Special Features
2primary windings; five secondary windings,also current and voltage on secondaries have been rectified
Terminal Type And Quantity
17 wire lead

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5950-00-488-9901?
The FSCG of the NSN 5950-00-488-9901 is 5950
Does NSN 5950-00-488-9901 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5950-00-488-9901 contain precious materials?
Precious metal content is unknown
Does NSN 5950-00-488-9901 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5950-00-488-9901 was assigned to the Federal Catalog?
It was assigned 56 years ago, on Mon, May 18, 1970

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

8267166-1
6210-00-959-7729
Light Lens
8267178D1
5999-00-959-7144
Electrical Cap
82671RU
5895-01-627-0694
Blade Server Ctr Nrp
82671ST
5930-01-354-9794
Toggle Switch
82672
5365-01-398-6426
Plate Spacer
826720
5340-00-664-6395
Buckle
826726
5355-00-382-6057
Scale Dial
826726-11
5365-01-645-6251
Sleeve Spacer
826726-127
1560-01-553-7348
Air Structural Component Support
826726-13
5365-01-645-6248
Sleeve Spacer
826726-7
1560-01-617-7126
Air Structural Component Support
826726-9
5340-01-645-6252
Mounting Bracket
826727
5355-00-382-6058
Scale Dial
826727-1
1560-00-806-5429
Torque Tube Housing
826729A4
2990-01-462-7761
Power Trim Kit