5950-00-405-5098

Find complete technical information, availability, and procurement data for: 5950-00-405-5098

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5950-00-405-5098 to receive an up to date pricing and availability quote by email.

5950-00-405-5098
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5950 Coils and Transformers
National Stock Number
5950-00-405-5098
Item Name Code
32496
Assigment Date
04/05/1971 (55 years ago)

A transformer which is designed so that part or all of its range of operating frequencies is 20 kilohertz (kilocycles) and below. The maximum value may extend into the radio frequency range. It is generally used in the input, output, amplifier, or oscillator stages of audio and sonar devices.

single phase to single phase single component input-output phase relationship, 60.0 hertz nominal single component frequency rating, 4.000 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to length, 2.875 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to width, internal shield grounded to inclosure single component winding shielding method

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Center To Center Distance Between Mounting Facilities Parallel To Length
4.000 inches nominal single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width
2.875 inches nominal single mounting facility single center group
Frequency Rating
60.0 hertz nominal single component
Input-Output Phase Relationship
single phase to single phase single component
Winding Shielding Method
internal shield grounded to inclosure single component
Body Length
5.000 inches nominal
Body Width
3.875 inches nominal
Body Height
5.125 inches nominal
Inclosure Type
fully inclosed
Mounting Facility Quantity
4 single group
Mounting Method
threaded stud single group
Winding Function And Quantity
2 primary and 3 secondary single component
Winding Operating Current
2.7 amperes ac maximum single component 1st primary
Winding Operating Current
200.0 milliamperes ac maximum single component 2nd primary
Winding Operating Current
4.0 amperes ac maximum single component 1st secondary
Winding Operating Current
4.0 amperes ac maximum single component 2nd secondary
Winding Operating Current
400.0 milliamperes ac maximum single component 3rd secondary
Winding Operating Voltage
1.20 ac kilovolts nominal single component 2nd primary
Winding Operating Voltage
12.00 ac volts nominal single component 2nd secondary
Winding Operating Voltage
120.00 ac volts nominal single component 1st primary
Winding Operating Voltage
70.00 ac volts nominal single component 3rd secondary
Winding Operating Voltage
5.00 ac volts nominal single component 1st secondary
Terminal Type And Quantity
15 turret

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
T-1213-H Power Transformer

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5950-00-405-5098?
The FSCG of the NSN 5950-00-405-5098 is 5950
Does NSN 5950-00-405-5098 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5950-00-405-5098 contain precious materials?
Item does not contain precious metal.
Does NSN 5950-00-405-5098 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5950-00-405-5098 was assigned to the Federal Catalog?
It was assigned 55 years ago, on Mon, Apr 5, 1971

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

U-122A/G
5935-00-902-3060
Electrical Receptacle Connector
U-123/U
5935-00-296-7987
Electrical Plug Connector
U-124/U
5935-00-259-9798
Electrical Plug Connector
U-125 SH0RT SS
3010-00-810-6820
Flexible Shaft Coupling
U-126/U
5935-00-583-8291
Electrical Receptacle Connector
U-12660
5315-01-196-0278
Headless Straight Pin
U-1275
8010-00-181-8080
Paint Products Thinner
U-127U-PSA
9330-01-532-5183
Sound Absorbing Foam
U-12857
3120-00-287-6766
Sleeve Bearing
U-12948
5310-01-257-3243
Flat Washer
U-12BAA-3E06-BL-9 REPAIR KIT
4820-01-690-3091
Ball Valve Parts Kit
U-12BAA-3E06-BL5
4820-01-690-1944
Ball Valve
U-12BAA-3E06-BL5 REPAIR KIT
4810-01-690-4492
Valve Repair Kit
U-12BAA-3E06-BL5 REV 0
4820-01-690-1944
Ball Valve
U-12BAA-3E06-BL5 REV O
4820-01-690-1944
Ball Valve