1. Home /
  2. Catalog /
  3. Coils and Transformers /
  4. 5950-00-156-0649

5950-00-156-0649

Find complete technical information, availability, and procurement data for: 5950-00-156-0649

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5950-00-156-0649 to receive an up to date pricing and availability quote by email.

5950-00-156-0649
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5950 Coils and Transformers
National Stock Number
5950-00-156-0649
Item Name Code
32496
Assigment Date
10/16/1971 (54 years ago)

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes:transformer (1), pulse.

not established reliability indicator, 60.0 hertz nominal single component frequency rating, 1.312 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to length, 1.250 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to width, single phase to single phase single component input-output phase relationship

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Reliability Indicator
not established
Center To Center Distance Between Mounting Facilities Parallel To Length
1.312 inches nominal single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width
1.250 inches nominal single mounting facility single center group
Frequency Rating
60.0 hertz nominal single component
Input-Output Phase Relationship
single phase to single phase single component
Winding Shielding Method
internal shield brought out to terminal single component
Body Length
1.650 inches maximum
Body Width
1.500 inches maximum
Body Height
1.950 inches maximum
Inclosure Type
fully inclosed
Mounting Facility Quantity
4 single group
Mounting Method
threaded hole single group
Winding Function And Quantity
1 primary and 1 secondary single component
Thread Quantity Per Inch
40 single group
Nominal Thread Size
0.112 inches single group
Winding Operating Current
8.0 milliamperes dc maximum single component single secondary
Winding Operating Voltage
230.00 ac volts nominal single component single primary
Winding Operating Voltage
24.40 ac volts nominal single component single secondary
Thread Series Designator
unc single group
Terminal Type And Quantity
6 tab, solder lug

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5950-00-156-0649?
The FSCG of the NSN 5950-00-156-0649 is 5950
Does NSN 5950-00-156-0649 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5950-00-156-0649 contain precious materials?
Precious metal content is unknown
Does NSN 5950-00-156-0649 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5950-00-156-0649 was assigned to the Federal Catalog?
It was assigned 54 years ago, on Sat, Oct 16, 1971

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

CT-9420
4730-01-400-3145
Hose Clamp
CT 9420 B
4730-01-400-3145
Hose Clamp
CT-9424
5340-01-570-4015
Loop Clamp
CT 9432
4730-01-697-8076
Hose Clamp
CT 9432 B
4730-01-687-7749
Hose Clamp
CT-9436
4730-01-543-5588
Clamp Liner
CT-9440
4730-01-546-0227
Hose Clamp
CT 9444
4730-01-348-9510
Hose Clamp
CT 9444 B
4730-01-348-9510
Hose Clamp
CT-9448
4730-01-546-0254
Hose Clamp
CT 9452
4730-01-697-7994
Hose Clamp
CT 9452 B
4730-01-687-7754
Hose Clamp
CT-9533
5950-01-306-6242
Electrical Coil
CT 96-CP 29
5985-01-369-1577
Radio Frequency Reflect Isolator
CT-9840A
5935-01-354-4013
Electrical Plug Connector