905464-2

View detailed technical data, stock status, and sourcing information for: 905464-2

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part 905464-2 to receive an up to date pricing and availability quote by email.

905464-2
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5950 Coils and Transformers
National Stock Number
5950-00-082-8774
Item Name Code
32496
Assigment Date
11/22/1972 (53 years ago)

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes:transformer (1), pulse.

0.166 inches nominal single group mounting hole diameter, 2.050 inches maximum overall height, 2.155 inches minimum and 2.165 inches maximum single mounting facility single center group center to center distance between mounting facilities parallel to width, 2.895 inches minimum and 2.905 inches maximum single mounting facility single center group center to center distance between mounting facilities parallel to length, not established reliability indicator

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Reliability Indicator
not established
Center To Center Distance Between Mounting Facilities Parallel To Length
2.895 inches minimum and 2.905 inches maximum single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width
2.155 inches minimum and 2.165 inches maximum single mounting facility single center group
Overall Height
2.050 inches maximum
Mounting Hole Diameter
0.166 inches nominal single group
Frequency Rating
400.0 hertz nominal single component
Input-Output Phase Relationship
three phase to six phase single component
Transformer Winding Connection Type
wye-delta
Winding Shielding Method
internal shield brought out to terminal single component
Body Length
3.500 inches maximum
Body Width
2.750 inches maximum
Maximum Operating Temp
5.0 celsius
Inclosure Type
fully inclosed
Mounting Facility Quantity
4 single group
Mounting Method
flange and unthreaded hole single group
Winding Function And Quantity
1 primary and 1 secondary single component
Winding Operating Current
16.5 amperes ac maximum single component single secondary
Winding Operating Voltage
115.00 ac volts nominal single component single primary
Terminal Type And Quantity
23 turret

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
12425-5 Power Transformer
16P241 Power Transformer
905464-2 Power Transformer

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5950-00-082-8774?
The FSCG of the NSN 5950-00-082-8774 is 5950
Does NSN 5950-00-082-8774 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5950-00-082-8774 contain precious materials?
Item does not contain precious metal.
Does NSN 5950-00-082-8774 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5950-00-082-8774 was assigned to the Federal Catalog?
It was assigned 53 years ago, on Wed, Nov 22, 1972

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

781102-001
5998-01-068-4946
Circuit Card Assembly
781102-1
2915-01-312-5211
Fluid Filter
781103
2840-01-099-1805
Aircraft Gas T Turbine Blade Set
781103-001
5998-01-068-4947
Circuit Card Assembly
7811030A
5945-00-674-1062
Electromagnetic Relay
781104-001
5998-01-068-4948
Circuit Card Assembly
781105-001
5998-01-068-4949
Circuit Card Assembly
7811059
4820-00-615-8443
Safety Relief Valve
781106-001
5998-01-066-2230
Circuit Card Assembly
781107-001
5998-01-066-2231
Circuit Card Assembly
7811071
2990-01-085-0855
Lever
781109-001
1290-01-029-9408
Multiplex Timing as
78111-06
6105-00-284-1977
Motor Armature
78111-1
5330-00-415-5897
Gasket
78111-10
6105-01-275-0953
Motor Armature