1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-591-6121

5925-01-591-6121

Find complete technical information, availability, and procurement data for: 5925-01-591-6121

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-591-6121 to receive an up to date pricing and availability quote by email.

5925-01-591-6121
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-591-6121
Item Name Code
00136
Assigment Date
02/02/2011 (15 years ago)

35.4 millimeters nominal body width, 17.7 millimeters nominal center to center distance between terminals parallel to width, multipole-multiple actuator type body style, 105.0 millimeters nominal body length, 44.0 millimeters nominal body height

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-multiple actuator type
Body Length
105.0 millimeters nominal
Body Width
35.4 millimeters nominal
Body Height
44.0 millimeters nominal
Center To Center Distance Between Terminals Parallel To Width
17.7 millimeters nominal
End Item Identification
aircraft c295
Boss Height
16.0 millimeters nominal
Pole Quantity
2
Mounting Facility Type And Quantity
1 din rail
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac and 10.0 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts
277.0 ac and 480.0 ac and 96.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
10000.0 ac and 10000.0 dc all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic all locations
Trip Release Characteristic
instantaneous and time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
1000.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
2 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one and at pole two
External Actuator Linkage Arrangement
one and two linked
Internal Trip Release Configuration
relay trip all locations
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 minimum at 200 pct and 90.000 maximum at 200 pct all locations
Part Name Assigned By Controlling Agency
faz na miniature branch circuit breaker for highly inductive load
Special Features
suitable for applications where high levels of inrush current are expected; prevents nuisance tripping in high inductive apps
Frequency In Hertz
50.0 or 60.0 all locations
Material
plastic case
Terminal Type And Quantity
4 screw

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
FAZ-D10/2-NA Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-591-6121?
The FSCG of the NSN 5925-01-591-6121 is 5925
Does the NSN 5925-01-591-6121 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-591-6121 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-591-6121 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-591-6121 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-591-6121 was assigned to the Federal Catalog?
It was assigned 15 years ago, on Wed, Feb 2, 2011

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

1960-3001S
5895-01-191-1402
Electrical Frequen Discriminator
1960-3002
5950-01-188-1606
Electrical Coil
1960-3003
5985-01-240-7680
Capacitor Drive Ass
1960-3004
6625-01-232-6891
Coil Drive Assembly
1960-3005
5950-01-229-0051
Transformer Assembly
1960-3006
5895-01-097-4567
Wire Adapter
1960-3007
5950-01-188-1607
Reactor
1960-36-0
5995-00-444-6866
Electrical Lead
1960-36-2
5995-00-444-6858
Electrical Lead
1960-36BLACK
5995-00-444-6857
Electrical Lead
1960-36RED
5995-00-444-6858
Electrical Lead
1960-3C4
5930-00-104-1415
Rotary Switch
1960-3C5
5930-00-843-0276
Rotary Switch
1960-4
5120-00-686-5821
Third Stage Ram
1960-4-11-2
5325-00-422-4190
Turnlock Fastener Receptacle