1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-583-6372

5925-01-583-6372

Find complete technical information, availability, and procurement data for: 5925-01-583-6372

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-583-6372 to receive an up to date pricing and availability quote by email.

5925-01-583-6372
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-583-6372
Item Name Code
00136
Assigment Date
03/31/2010 (16 years ago)

1.250 inches minimum and 1.281 inches maximum body width, +0.3503 to 0.3537 inches thread pitch diameters, 1.531 inches minimum and 1.562 inches maximum body length, 0.332 inches minimum and 0.380 inches maximum bushing length, multipole-single actuator type body style

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Thread Pitch Diameters
+0.3503 to 0.3537 inches
Body Style
multipole-single actuator type
Bushing Length
0.332 inches minimum and 0.380 inches maximum
Body Length
1.531 inches minimum and 1.562 inches maximum
Body Width
1.250 inches minimum and 1.281 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.875 inches minimum and 0.906 inches maximum
Center To Center Distance Between Terminals Parallel To Width
0.594 inches minimum and 0.906 inches maximum
Mounting Surface To Terminal End Distance
1.797 inches minimum and 1.828 inches maximum
Pole Quantity
2
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac and 5.0 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac and 50.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac and 500.0 dc all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
between pole one and two
Internal Trip Release Configuration
series trip all locations
Nominal Thread Size
0.375 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.500 minimum at 200 pct and 0.900 maximum at 200 pct all locations
Frequency In Hertz
400.0 all locations
Thread Series Designator
unef
Terminal Type And Quantity
4 wire hook

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
AP-12-1-7-1-702 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-583-6372?
The FSCG of the NSN 5925-01-583-6372 is 5925
Does the NSN 5925-01-583-6372 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-583-6372 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-583-6372 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-583-6372 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-583-6372 was assigned to the Federal Catalog?
It was assigned 16 years ago, on Wed, Mar 31, 2010

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

13011024-2
6150-01-320-2574
Electrical Power Cable Assembly
13011031-4
5340-01-320-7308
Butt Hinge Leaf
13011031-5
5340-01-312-7107
Butt Hinge Leaf
13011032
6920-01-304-7094
Trainer Subassembly
13011035
5930-01-577-4145
Switch Assembly
13011036
5930-01-577-4145
Switch Assembly
13011037
6150-01-560-8969
Wiring Harness
1301104-1
5935-00-683-5106
Electrical Connector Cover
13011040
6850-01-531-7594
Magnetic Inspection Compound
13011043
5998-01-583-9254
Circuit Card Assembly
13011045
5331-01-591-2156
O-Ring
13011046
3040-01-313-8843
Rigid Connecting Link
13011046-1
3040-01-313-8843
Rigid Connecting Link
13011046-2
5340-01-338-6561
Mounting Bracket
1301105-00
5962-01-283-7127
Digital Microcircuit