Find complete technical information, availability, and procurement data for: 5925-01-449-4386

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-449-4386 to receive an up to date pricing and availability quote by email.

5925-01-449-4386
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-449-4386
Item Name Code
00136
Assigment Date
10/01/1997 (28 years ago)

A metallic item, cylindrical, with or without a flange at one end. It is designed to be inserted into a hole to reduce friction and/or the inside diameter of the hole, and protect the surrounding body structure from damage resulting from stress, strain and/or vibration. It must have a through hole parallel to its axis. It is designed for subsequent drilling operation. For items that are tapered see bushing (1), tapered. Excludes:bushing, sleeve.

1.500 inches nominal body width, 2.480 inches minimum and 2.500 inches maximum body length, multipole-multiple actuator type body style, 0.750 inches nominal center to center distance between terminals parallel to width, 1.940 inches nominal center to center distance between terminals parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-multiple actuator type
Body Length
2.480 inches minimum and 2.500 inches maximum
Body Width
1.500 inches nominal
Center To Center Distance Between Terminals Parallel To Length
1.940 inches nominal
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.050 inches minimum and 2.070 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
Boss Height
0.150 inches maximum
Mounting Surface To Terminal End Distance
2.475 inches maximum
Pole Quantity
2
Mounting Facility Type And Quantity
4 threaded hole
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic all locations
Trip Release Characteristic
instantaneous all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Internal Trip Release Configuration
series trip all locations
Nominal Thread Size
0.190 inches
Frequency In Hertz
50.0 or 60.0 all locations
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
4 threaded stud

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
APL-11-1-64-503 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-449-4386?
The FSCG of the NSN 5925-01-449-4386 is 5925
Does the NSN 5925-01-449-4386 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-449-4386 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-449-4386 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-449-4386 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-449-4386 was assigned to the Federal Catalog?
It was assigned 28 years ago, on Wed, Oct 1, 1997

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

21203PC55
3120-00-418-4230
Sleeve Bearing
21204
3020-01-094-0107
Gear Rack
21204-0301-0302
4810-01-300-1301
Solenoid Valve
21204-0301-2702
4810-01-270-6744
Solenoid Valve
21204-0301-2800
4810-01-206-3285
Solenoid Valve
21204-1
2835-00-654-6759
Forward Locating Plate
21204-7
5998-00-461-2011
Circuit Card Assembly
21204-771031
5962-00-365-5721
Linear Microcircuit
212040
5950-01-264-0054
Power Transformer
212040-03
1680-01-722-6483
Control Cable Assembly
212040-11
1660-01-620-1739
Communicat Assembly
2120400
4920-01-057-3395
Pneumatic System Co Test Station
2120400-005
4920-01-057-3395
Pneumatic System Co Test Station
2120400-009
4920-01-166-2444
Pneumatic System Co Test Station
2120400-015
4920-01-303-7040
Test Station P P