1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-390-3498

5925-01-390-3498

Find complete technical information, availability, and procurement data for: 5925-01-390-3498

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-390-3498 to receive an up to date pricing and availability quote by email.

5925-01-390-3498
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-390-3498
Item Name Code
00136
Assigment Date
05/17/1994 (32 years ago)

A switch that is actuated by changes in ambient temperature. Excludes:circuit breaker; control, temperature (as modified); fuse (as modified); protector, thermal-overload, electrical motor; relay, thermal; and thermostat, flow control. See also control, temperature (as modified) and regulator, temperature (as modified).

0.380 inches maximum bushing length, 0.375 inches nominal center to center distance between terminals parallel to length, 1.780 inches maximum body length, multipole-single actuator type body style, 1.281 inches maximum body width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-single actuator type
Bushing Length
0.380 inches maximum
Body Length
1.780 inches maximum
Body Width
1.281 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.375 inches nominal
Center To Center Distance Between Terminals Parallel To Width
0.625 inches nominal
Mounting Surface To Terminal End Distance
1.780 inches maximum
Pole Quantity
2
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Maximum Continuous Load Current Rating Per Pole
3.0 amperes ac and 3.0 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts
40.0 ac and 50.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac and 500.0 dc all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
between pole one and two
Internal Trip Release Configuration
series trip all locations
Nominal Thread Size
0.375 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.600 minimum at 200 pct and 6.000 maximum at 200 pct all locations
Frequency In Hertz
60.0 or 400.0 all locations
Thread Series Designator
unef
Terminal Type And Quantity
4 tab w/screw

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
24998.500FIND11 Circuit Breaker
24998.506-2 Circuit Breaker
AP-16-1RC-52-302 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-390-3498?
The FSCG of the NSN 5925-01-390-3498 is 5925
Does the NSN 5925-01-390-3498 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-390-3498 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-390-3498 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-390-3498 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-390-3498 was assigned to the Federal Catalog?
It was assigned 32 years ago, on Tue, May 17, 1994

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

MDR-1211
5820-01-511-2135
Radio Receiver
MDR-123-4
5945-01-045-8236
Rotary Relay
MDR-131-1
5945-01-051-3905
Rotary Relay
MDR-131-1(MOD)
5945-01-618-6157
Rotary Relay
MDR-131-2
5945-00-943-6565
Rotary Relay
MDR-134-1
5945-01-051-3423
Rotary Relay
MDR-135-1
5945-00-840-7844
Rotary Relay
MDR-136-1
5945-00-856-0420
Rotary Relay
MDR-163-1
5945-01-689-5117
Rotary Relay
MDR-185-1
5945-00-146-4877
Rotary Relay
MDR-20-12
6130-01-580-7808
Power Supply
MDR-20-24
6130-01-690-2067
Power Supply
MDR-201LP
5965-01-497-1150
Acoustical Headset
MDR-204ZS
3110-01-241-5148
Annular Ball Bearing
MDR-2055D604M2A5P820LY378UB
3110-01-051-1644
Ball Assy Bearing