PP21-62F-10.0A-0A-S

View detailed technical data, stock status, and sourcing information for: PP21-62F-10.0A-0A-S

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part PP21-62F-10.0A-0A-S to receive an up to date pricing and availability quote by email.

PP21-62F-10.0A-0A-S
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-340-6960
Item Name Code
00136
Assigment Date
06/19/1991 (35 years ago)

"a device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes:circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller."

1.375 inches nominal body width, 1.304 inches nominal body length, 0.625 inches nominal center to center distance between terminals parallel to length, 0.400 inches nominal bushing length, single pole type body style

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Bushing Length
0.400 inches nominal
Body Length
1.304 inches nominal
Body Width
1.375 inches nominal
Center To Center Distance Between Terminals Parallel To Length
0.625 inches nominal
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
0.960 inches nominal
Pole Quantity
2
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
1 threaded bushing
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 push-pull
Actuator Function
trip-reset
Actuator Position Designation
between pole one and two
Internal Trip Release Configuration
series trip all locations
Nominal Thread Size
0.375 inches
Trip Delay Time In Seconds Per Rated Continuous Current
1.000 minimum at 200 pct and 15.000 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
dustproof and fungus proof
Special Features
item includes inertia delay
Frequency In Hertz
50.0 or 60.0 all locations
Material
plastic case
Thread Series Designator
unef
Terminal Type And Quantity
4 tab w/screw

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
PP21-62F-10.0A-0A-S Circuit Breaker
PP21-62F-10.0A-O Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-340-6960?
The FSCG of the NSN 5925-01-340-6960 is 5925
Does the NSN 5925-01-340-6960 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-340-6960 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-340-6960 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-340-6960 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-340-6960 was assigned to the Federal Catalog?
It was assigned 35 years ago, on Wed, Jun 19, 1991

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

CFV-13460-CDS P65N1283K17 2IN
4820-01-411-4911
Globe Valve
CFV 13821-005 P.O. ITEM 001
4820-01-421-3444
Plug Valve
CFV 18229-001
4820-01-480-3160
Plug Valve
CFV 18229-007
4820-01-480-3119
Plug Valve
CFV 18229-008
4820-01-480-3115
Plug Valve
CFV-18575-001 IT006
4820-01-482-3053
Plug Valve
CFV-19231-001 ITEM 001
4820-01-487-3642
Plug Valve
CFV-19255-001 IT 01
4820-01-492-7619
Plug Valve
CFV-19267-002 IT 002
4820-01-487-4950
Plug Valve
CFV-19267-003 IT 003
4820-01-487-4956
Plug Valve
CFV-19276-001 IT 001
4820-01-487-4960
Plug Valve
CFV-19276-002 ITEM 002
4820-01-487-4541
Plug Valve
CFV 19278-001
4820-01-495-3737
Plug Valve
CFV-19278-002 ITEM 002
4820-01-495-3364
Plug Valve
CFV-19278-003
4820-01-495-6093
Plug Valve