DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-314-8126 to receive an up to date pricing and availability quote by email.

5925-01-314-8126
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-314-8126
Item Name Code
00136
Assigment Date
02/06/1990 (36 years ago)

0.250 inches nominal unthreaded mounting hole diameter, 5.190 inches nominal overall height, 17.310 inches nominal overall length, 8.250 inches nominal overall width, rectangular dimensional envelope body style

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
rectangular dimensional envelope
Overall Length
17.310 inches nominal
Overall Height
5.190 inches nominal
Overall Width
8.250 inches nominal
Unthreaded Mounting Hole Diameter
0.250 inches nominal
Switch Contact Arrangement
single pole, double throw
Fragility Factor
moderately rugged
Pole Quantity
3
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
4 unthreaded hole
Storage Type
general purpose warehouse
Features Provided
adjustable trip release
Maximum Continuous Load Current Rating Per Pole
400.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
480.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
150000.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic all locations
Trip Release Characteristic
instantaneous all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole two
Auxiliary Switch Function And Quantity
1 alarm
Adjustable Trip Setting Current Range Per Pole In Amps
+2000.0 to 3200.0 ac all locations
Internal Trip Release Configuration
series trip all locations
Switch Location And Position Designation
internal at pole one
Inclosure Protection Type For Which Designed
dustproof and fungus proof
Switch Current Rating And Type In Amps
15.0 ac and 0.5 dc
Switch Voltage Rating And Type In Volts
250.0 ac and 125.0 dc
Frequency In Hertz
60.0 all locations
Material
plastic case
Terminal Type And Quantity
6 compression

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5925-01-289-9339 No Name Available 04/01/2009

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
XJL433400MTOASJ-1 Circuit Breaker
XJL434400MT0 AL-1 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-314-8126?
The FSCG of the NSN 5925-01-314-8126 is 5925
Does the NSN 5925-01-314-8126 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-314-8126 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-314-8126 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-314-8126 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-314-8126 was assigned to the Federal Catalog?
It was assigned 36 years ago, on Tue, Feb 6, 1990

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

R26BTYPERW33V800
5905-00-642-2776
Resistor,fixed,wire Wound,induct
R26BTYPERW33VR35
5905-00-636-6668
Resistor,fixed,wire Wound,induct
R26BTYPERW35V901
5905-00-642-2034
Resistor,fixed,wire Wound,induct
R26BTYPERW47GR50
5905-00-549-7370
Resistor,fixed,wire Wound,induct
R26BTYPERW55G103
5905-00-642-2023
Resistor,fixed,wire Wound,induct
R26BTYPERW55G902
5905-00-270-6295
Wire Wound Fixed Resistor
R26BTYPERW56V2R5
5905-00-549-9736
Resistor,fixed,wire Wound,induct
R26BTYPERW56V351
5905-00-636-8374
Resistor,fixed,wire Wound,induct
R26BTYPERW56V500
5905-00-642-1207
Resistor,fixed,wire Wound,induct
R26C
4940-01-013-1615
Sewer Machine Rod
R26P
2940-01-395-8798
Fluid Filter Element
R26QWDK12
5945-00-760-1994
Electromagnetic Relay
R26SMB12A
5945-00-617-7046
Electromagnetic Relay
R26SU12
5945-00-081-7488
Electromagnetic Relay
R26T
2910-01-331-1771
Fluid Filter Element