1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-310-1890

5925-01-310-1890

Find complete technical information, availability, and procurement data for: 5925-01-310-1890

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-310-1890 to receive an up to date pricing and availability quote by email.

5925-01-310-1890
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-310-1890
Item Name Code
00136
Assigment Date
10/31/1989 (36 years ago)

0.670 inches minimum and 0.690 inches maximum body width, 0.458 inches minimum and 0.478 inches maximum bushing length, 1.095 inches minimum and 1.155 inches maximum center to center distance between terminals parallel to length, 1.365 inches minimum and 1.385 inches maximum body length, single pole type body style

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Bushing Length
0.458 inches minimum and 0.478 inches maximum
Body Length
1.365 inches minimum and 1.385 inches maximum
Body Width
0.670 inches minimum and 0.690 inches maximum
Center To Center Distance Between Terminals Parallel To Length
1.095 inches minimum and 1.155 inches maximum
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
1.525 inches minimum and 1.585 inches maximum
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
1 threaded bushing
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac and 2.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac and 65.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac and 1000.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.500 inches
Trip Delay Time In Seconds Per Rated Continuous Current
1.000 minimum at 200 pct and 10.500 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
dustproof
Frequency In Hertz
50.0 or 60.0 single location
Material
plastic case
Thread Series Designator
un
Terminal Type And Quantity
2 quick disconnect, male

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
T11-2-2.00A-01-20V Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-310-1890?
The FSCG of the NSN 5925-01-310-1890 is 5925
Does the NSN 5925-01-310-1890 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-310-1890 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-310-1890 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-310-1890 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-310-1890 was assigned to the Federal Catalog?
It was assigned 36 years ago, on Tue, Oct 31, 1989

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

LED-10-04
5940-01-313-2056
Feedthru Terminal
LED-10-48-SG-40625
6220-01-594-3562
Light Indicator
LED-1002HD
7025-01-568-5172
Display Unit
LED-1002HDM
7025-01-568-5172
Display Unit
LED-1003HD
7025-01-568-5172
Display Unit
LED-1003HDG
7025-01-568-5172
Display Unit
LED-11 XC556R
6210-01-339-1189
Indicator Light
LED-12-54-HA-32965
5930-01-551-0812
Push Switch
LED-120-MB-W
6210-01-631-2955
Light Emitting Diode Lamp
LED-14-24-HK-E0F3F(1R1POWER,ON)
5930-01-610-8544
Pushbut Switch Nrp
LED-144
6240-01-708-3971
Light Emitting Diode Lamp
LED-144W-ZK
6650-01-662-5643
Microscope Light
LED 14E26P3030KNFL
6240-01-622-7371
Light Emitting Diode Lamp
LED-16-54-HA-32965
5930-01-551-0852
Push Switch
LED-16-54-HA-32966
5930-01-551-0862
Push Switch