1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-308-3469

5925-01-308-3469

Find complete technical information, availability, and procurement data for: 5925-01-308-3469

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-308-3469 to receive an up to date pricing and availability quote by email.

5925-01-308-3469
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-308-3469
Item Name Code
00136
Assigment Date
09/27/1989 (36 years ago)

"a device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes:circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller."

single pole type body style, 2.050 inches minimum and 2.070 inches maximum distance between centerlines of mounting facilities parallel to body length, 1.925 inches minimum and 1.955 inches maximum center to center distance between terminals parallel to length, 2.480 inches minimum and 2.500 inches maximum body length, 0.735 inches minimum and 0.765 inches maximum body width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Body Length
2.480 inches minimum and 2.500 inches maximum
Body Width
0.735 inches minimum and 0.765 inches maximum
Center To Center Distance Between Terminals Parallel To Length
1.925 inches minimum and 1.955 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.050 inches minimum and 2.070 inches maximum
Fragility Factor
moderately rugged
Boss Height
0.135 inches minimum and 0.181 inches maximum
Mounting Surface To Terminal End Distance
2.594 inches minimum and 2.656 inches maximum
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac single location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 minimum at 200 pct and 100.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
fungus proof
Frequency In Hertz
50.0 or 60.0 single location
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
2 threaded stud

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
MPL-1-1-66-153-M Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-308-3469?
The FSCG of the NSN 5925-01-308-3469 is 5925
Does the NSN 5925-01-308-3469 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-308-3469 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-308-3469 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-308-3469 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-308-3469 was assigned to the Federal Catalog?
It was assigned 36 years ago, on Wed, Sep 27, 1989

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

1676854
4710-00-456-2122
Metallic Bent Tube
1676856 PIECE 35
3110-00-873-5553
Annular Ball Bearing
1676857
4710-00-443-1256
Metallic Bent Tube
1676858
5945-00-735-4708
Electromagnetic Relay
167686-2
5962-01-076-3077
Digital Microcircuit
1676862
5120-00-076-2175
Spring Compressor
1676864
6515-01-724-9130
Temp Probe Adaptor Cable
1676865
6515-01-724-9133
Patient Ecg Cable
1676865PC5
4730-00-222-0162
Tube Tee
1676866
6515-01-725-0273
Canister Holder
1676867
5999-00-923-8683
Electrical Contact Assembly
1676868
6515-01-725-0203
Portable Icu Clamp Set
167687-03
5962-01-290-8568
Digital Microcircuit
167687-04
5962-01-303-9364
Digital Microcircuit
167687-1
5999-01-237-3805
Electrical Shield Plate