1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-305-1965

5925-01-305-1965

Find complete technical information, availability, and procurement data for: 5925-01-305-1965

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-305-1965 to receive an up to date pricing and availability quote by email.

5925-01-305-1965
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-305-1965
Item Name Code
00136
Assigment Date
08/01/1989 (37 years ago)

2.280 inches maximum body width, 0.750 inches maximum center to center distance between terminals parallel to width, 1.940 inches maximum center to center distance between terminals parallel to length, 2.530 inches maximum body length, single pole type body style

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Body Length
2.530 inches maximum
Body Width
2.280 inches maximum
Center To Center Distance Between Terminals Parallel To Length
1.940 inches maximum
Center To Center Distance Between Terminals Parallel To Width
0.750 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
0.750 inches maximum
Boss Height
0.700 inches maximum
Mounting Surface To Terminal End Distance
0.630 inches maximum
Pole Quantity
3
Mounting Facility Type And Quantity
6 threaded stud
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
3.5 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic-hydraulic all locations
Auxiliary Trip Coil Voltage Type And Rating In Volts
125.0 ac nominal all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Ultimate Trip Time Per Pole In Seconds
5.000 maximum all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Internal Trip Release Configuration
series/relay trip single location
Nominal Thread Size
0.138 inches
Trip Release Duty Cycle
continuous all locations
Trip Delay Time In Seconds Per Rated Continuous Current
50.000 maximum at 225 pct single location
Frequency In Hertz
60.0 all locations
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
6 threaded stud

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
260-0952-110 Circuit Breaker
AM3-Z270-1 Circuit Breaker
APL-111R-853-110 Circuit Breaker
APL111-1REC4-853-110 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-305-1965?
The FSCG of the NSN 5925-01-305-1965 is 5925
Does the NSN 5925-01-305-1965 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-305-1965 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-305-1965 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-305-1965 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-305-1965 was assigned to the Federal Catalog?
It was assigned 37 years ago, on Tue, Aug 1, 1989

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

4HC401
5331-01-159-8364
O-Ring
4HC41
5310-01-159-6590
Flat Washer
4HC416
5331-01-157-6749
O-Ring
4HC42
5310-01-157-5661
Hexagon Self-Locking Nut
4HC47
4730-00-172-0043
Lubrication Fitting
4HC63
4730-01-203-5116
Lubrication Fitting
4HC76
4720-01-157-4320
Nonmetallic Hose Assembly
4HCC-10-M402
4310-01-197-4395
Reciprocating Compressor
4HCC-10-M450X
4310-01-197-4395
Reciprocating Compressor
4HCC-17-M400X
4310-01-337-3830
Reciprocating Compressor
4HCFB
6680-01-099-6695
Metering Tube
4HD-I-120V
5945-01-533-3332
Electrical Solenoid
4HD-I-12D
5945-01-395-9686
Electrical Solenoid
4HD-INT-24D
5945-00-430-4113
Electrical Solenoid
4HD0102-501
1680-01-479-7174
Electrical-Electro Control Panel