1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-286-8009

5925-01-286-8009

Find complete technical information, availability, and procurement data for: 5925-01-286-8009

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-286-8009 to receive an up to date pricing and availability quote by email.

5925-01-286-8009
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-286-8009
Item Name Code
00136
Assigment Date
10/08/1988 (37 years ago)

A nonmetallic circular item with an aperature, having a solid round cross-section. They are used primarily for sealing. For items with other than round cross section, see packing,preformed. For noncircular items with a round cross-section, see seal,nonmetallic round section and rubber,round section.

2.250 inches maximum body width, 0.750 inches nominal center to center distance between terminals parallel to width, multipole-multiple actuator type body style, 2.490 inches nominal body length, 1.940 inches nominal center to center distance between terminals parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-multiple actuator type
Body Length
2.490 inches nominal
Body Width
2.250 inches maximum
Center To Center Distance Between Terminals Parallel To Length
1.940 inches nominal
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.060 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
Fragility Factor
moderately rugged
Boss Height
0.150 inches nominal
Mounting Surface To Terminal End Distance
2.810 inches maximum
Pole Quantity
3
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
6 threaded hole
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
25.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
3 toggle
Actuator Function
trip-reset
Actuator Position Designation
at each pole
External Actuator Linkage Arrangement
one, two, and three linked
Internal Trip Release Configuration
series trip all locations
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.200 minimum at 200 pct and 0.700 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
dustproof
Frequency In Hertz
50.0 or 60.0 all locations
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
6 threaded stud

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
MPL-111-1-66-253 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-286-8009?
The FSCG of the NSN 5925-01-286-8009 is 5925
Does the NSN 5925-01-286-8009 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-286-8009 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-286-8009 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-286-8009 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-286-8009 was assigned to the Federal Catalog?
It was assigned 37 years ago, on Sat, Oct 8, 1988

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

OP-125/PSR/A/100M
5895-01-696-0461
Multiplexer
OP 126
1670-01-669-1618
Parachute,reserve,personnel,troo
OP-12MS-2A
4630-01-307-3723
Sewage Pumping Unit
OP-134/B/100M
7025-01-679-4344
Digital Multiplexer
OP-134/PSR/U/A/V35/8M
7025-01-610-5043
Digital Multiplexer
OP-14-BI-CP
5962-01-357-2250
Linear Microcircuit
OP 142
5120-01-623-5098
Torque Wrench Adapter
OP-143/FCC-100(V)
6130-01-148-6510
Power Supply Group
OP-144/FCC-100(V)
6130-01-148-6511
Power Supply Group
OP-14AJ/883
5962-01-238-9584
Linear Microcircuit
OP-14AZ
5962-01-329-0470
Linear Microcircuit
OP-14BZ
5962-01-317-6911
Linear Microcircuit
OP-14CZ
5962-01-260-9526
Linear Microcircuit
OP-14EP
5962-01-270-0213
Linear Microcircuit
OP-14EZ
5962-01-292-1648
Linear Microcircuit