1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-278-7148

5925-01-278-7148

Find complete technical information, availability, and procurement data for: 5925-01-278-7148

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-278-7148 to receive an up to date pricing and availability quote by email.

5925-01-278-7148
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-278-7148
Item Name Code
00136
Assigment Date
05/08/1988 (38 years ago)

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes:contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.

1.000 inches nominal center to center distance between terminals parallel to width, multipole-multiple actuator type body style, 2.359 inches nominal body height, 2.000 inches nominal body width, 3.281 inches nominal body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-multiple actuator type
Body Length
3.281 inches nominal
Body Width
2.000 inches nominal
Body Height
2.359 inches nominal
Center To Center Distance Between Terminals Parallel To Width
1.000 inches nominal
Fragility Factor
moderately rugged
Boss Height
0.187 inches nominal
Pole Quantity
2
Mounting Facility Type And Quantity
4 clip
Storage Type
general purpose warehouse
Maximum Continuous Load Current Rating Per Pole
100.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
10000.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
thermal-magnetic all locations
Trip Release Characteristic
instantaneous and time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
2 toggle
Actuator Function
trip-reset
Actuator Position Designation
at each pole
External Actuator Linkage Arrangement
one and two linked
Trip Delay Time In Seconds Per Rated Continuous Current
120.000 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
general purpose
Trip Release Ambient Temp Rating
40.0 celsius nominal all locations
Frequency In Hertz
60.0 all locations
Material
plastic case
Terminal Type And Quantity
4 compression

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
THQB22100 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-278-7148?
The FSCG of the NSN 5925-01-278-7148 is 5925
Does the NSN 5925-01-278-7148 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-278-7148 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-278-7148 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-278-7148 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-278-7148 was assigned to the Federal Catalog?
It was assigned 38 years ago, on Sun, May 8, 1988

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

CR-52A/U17.753700MHZ
5955-00-075-9051
Quartz Crystal Unit
CR-52A/U17.805800MHZ
5955-00-075-9052
Quartz Crystal Unit
CR-52A/U17.857900MHZ
5955-00-075-9088
Quartz Crystal Unit
CR-52A/U17.910000MHZ
5955-00-075-9089
Quartz Crystal Unit
CR-52A/U17.962100MHZ
5955-00-075-9090
Quartz Crystal Unit
CR-52A/U17.999000MHZ
5955-00-097-7282
Quartz Crystal Unit
CR-52A/U18.014200MHZ
5955-00-075-9121
Quartz Crystal Unit
CR-52A/U18.066300MHZ
5955-00-075-9124
Quartz Crystal Unit
CR-52A/U18.118300MHZ
5955-00-075-9139
Quartz Crystal Unit
CR-52A/U18.170400MHZ
5955-00-075-9140
Quartz Crystal Unit
CR-52A/U18.222500MHZ
5955-00-076-8914
Quartz Crystal Unit
CR-52A/U19.006000MHZ
5955-00-813-8679
Quartz Crystal Unit
CR-52A/U19.333330MHZ
5955-00-857-4560
Quartz Crystal Unit
CR-52A/U19.36666MHZ
5955-00-857-4561
Quartz Crystal Unit
CR-52A/U19.633330MHZ
5955-00-947-8063
Quartz Crystal Unit