1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-270-5257

5925-01-270-5257

Find complete technical information, availability, and procurement data for: 5925-01-270-5257

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-270-5257 to receive an up to date pricing and availability quote by email.

5925-01-270-5257
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-270-5257
Item Name Code
00136
Assigment Date
01/08/1988 (38 years ago)

"a device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes:circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller."

0.765 inches nominal body width, single pole type body style, 1.812 inches nominal center to center distance between terminals parallel to length, 1.812 inches nominal distance between centerlines of mounting facilities parallel to body length, 2.203 inches nominal body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Body Length
2.203 inches nominal
Body Width
0.765 inches nominal
Center To Center Distance Between Terminals Parallel To Length
1.812 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.812 inches nominal
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
1.405 inches nominal
Pole Quantity
1
Arc Quenching Method
air
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
25.0 amperes ac and 25.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac and 30.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
600.0 ac and 600.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
thermal single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.164 inches
Trip Delay Time In Seconds Per Rated Continuous Current
375.000 nominal at 200 pct single location
Inclosure Protection Type For Which Designed
dustproof
Trip Release Ambient Temp Rating
25.0 celsius nominal single location
Frequency In Hertz
60.0 single location
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
2 tab w/screw

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
6363-1-25 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-270-5257?
The FSCG of the NSN 5925-01-270-5257 is 5925
Does the NSN 5925-01-270-5257 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-270-5257 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-270-5257 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-270-5257 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-270-5257 was assigned to the Federal Catalog?
It was assigned 38 years ago, on Fri, Jan 8, 1988

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

122-978
6625-00-110-5890
Ammeter
122-98
4330-01-408-6670
Fluid Filter
122-99
4330-01-408-6658
Fluid Filter
122-994
6625-00-264-5180
Ammeter
122-9943
2815-01-662-5847
Valve Spring Retainer Lock
122-995
5930-00-885-9055
Rotary Switch
122 ARR-3 DWDI
4140-01-286-7452
Centrifugal Fan
122-B
5930-01-398-1179
Electronic Switch
122-B-04
5935-01-452-1529
Connector Adapter
122 BC DWDI
4140-01-286-7452
Centrifugal Fan
122-BLACK
7520-01-226-5659
Tube Type Marker
122 BW 062 G2C
6210-01-021-1948
Indicator Light
122 BW 683 G2M
6210-01-033-2790
Indicator Light
122-C-69
5331-00-250-0237
O-Ring
122-CVN-028-D1150301
2040-01-607-0059
Louver Ms