DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-262-2814 to receive an up to date pricing and availability quote by email.

5925-01-262-2814
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-262-2814
Item Name Code
00136
Assigment Date
08/26/1987 (38 years ago)

multipole-single actuator type body style, 3.375 inches nominal body height, 5.062 inches nominal center to center distance between terminals parallel to length, 4.125 inches nominal body width, 6.000 inches nominal body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-single actuator type
Body Length
6.000 inches nominal
Body Width
4.125 inches nominal
Body Height
3.375 inches nominal
Center To Center Distance Between Terminals Parallel To Length
5.062 inches nominal
Center To Center Distance Between Terminals Parallel To Width
1.375 inches nominal
Unthreaded Mounting Hole Diameter
0.187 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.500 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.375 inches nominal
Fragility Factor
moderately rugged
Boss Height
0.125 inches nominal
Pole Quantity
3
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
4 unthreaded hole
Storage Type
general purpose warehouse
Cubic Measure
96.000 cubic inches
Maximum Continuous Load Current Rating Per Pole
150.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
18000.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic all locations
Trip Release Characteristic
instantaneous all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole two
Internal Trip Release Configuration
series trip all locations
Inclosure Protection Type For Which Designed
fungus resistant and general purpose
Unpackaged Unit Weight
14.000 pounds nominal
Special Features
front magnetic trip range adjustment 575.0 amperes minimum to 1800.0 amperes maximum
Frequency In Hertz
60.0 all locations
Material
plastic case
Terminal Type And Quantity
6 compression

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
HFB31800ML Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-262-2814?
The FSCG of the NSN 5925-01-262-2814 is 5925
Does the NSN 5925-01-262-2814 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-262-2814 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-262-2814 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-262-2814 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-262-2814 was assigned to the Federal Catalog?
It was assigned 38 years ago, on Wed, Aug 26, 1987

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

F106LB-380MM-BEC-TIN-SOW
5360-01-563-0091
Flat Spring
F106PC404
2825-00-544-7841
Turb Nozzle Segment
F106R00A
5920-00-296-6841
Cartridge Fuse
F107
3040-00-528-0398
Ball Joint
F1070
5961-01-514-2181
Transistor
F10702REVC
6625-00-553-0329
Multiple Scale Meter
F107055
6625-01-667-1288
Electronic Test Set
F107083 ITEM NO 2
5365-01-648-2535
Sleeve Bushing
F1070GSM
5915-00-939-5847
Band Suppression Filter
F1070ITEM2
6115-00-242-8145
Generator Field Winding
F1070ITEM20
5360-00-473-1322
Torsion Helical Spring
F1070ITEM3-0
6115-00-643-1399
Generator Field Winding
F1070ITEM37
9340-00-468-1418
Observation Window
F1070ITEM3U
5306-00-576-2788
Machine Bolt
F1070ITEM47
6105-00-473-1328
Tong Btm Arm Bendin