T11-U211-10A

View detailed technical data, stock status, and sourcing information for: T11-U211-10A

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part T11-U211-10A to receive an up to date pricing and availability quote by email.

T11-U211-10A
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-260-5247
Item Name Code
00136
Assigment Date
07/31/1987 (39 years ago)

A pliable rubber or composition ring-shaped element, split or jointless (solid) not encased in a metal shell, but having a spring, spreader and/or molded-in reinforcement. It is designed to be pressmounted between fixed and movable or moving parts to form a tight and effective seal.

0.693 inches nominal center to center distance between terminals parallel to length, single pole type body style, 0.740 inches nominal body length, 0.430 inches nominal body width, 0.250 inches nominal bushing length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Bushing Length
0.250 inches nominal
Body Length
0.740 inches nominal
Body Width
0.430 inches nominal
Center To Center Distance Between Terminals Parallel To Length
0.693 inches nominal
Fragility Factor
moderately rugged
End Item Identification
4930-01-139-2492
Mounting Surface To Terminal End Distance
1.360 inches nominal
Pole Quantity
1
Mounting Facility Type And Quantity
1 threaded bushing
Storage Type
general purpose warehouse
Thread Quantity Per Inch
27
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac and 10.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac and 24.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
60.0 ac and 100.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
thermal single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 push button
Actuator Function
reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.375 inches
Trip Delay Time In Seconds Per Rated Continuous Current
15.000 minimum at 200 pct and 75.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
shock resistant and vibration resistant
Trip Release Ambient Temp Rating
20.0 celsius nominal single location
Frequency In Hertz
60.0 single location
Material
plastic case
Thread Series Designator
uns
Terminal Type And Quantity
2 quick disconnect, male

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
T11-U211-10A Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-260-5247?
The FSCG of the NSN 5925-01-260-5247 is 5925
Does the NSN 5925-01-260-5247 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-260-5247 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-260-5247 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-260-5247 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-260-5247 was assigned to the Federal Catalog?
It was assigned 39 years ago, on Fri, Jul 31, 1987

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

ESSICEL-2
4240-01-517-9768
Industrial Goggles Lens
ESSICEL-3
4240-01-555-3272
Industrial Goggles Lens
ESSICEL1-50
4240-01-525-4819
Spectacle Replacement Lens
ESSICEL1-50N
4240-01-549-0863
Industrial Goggles Lens
ESSICEL2-50
4240-01-525-5098
Spectacle Replacement Lense
ESSICEL2-50N
4240-01-549-0876
Industrial Goggles Lens
ESSICES
4240-01-518-9838
Essice Eyeshield Carrying Pouch
ESSIMS
7030-01-658-6111
Elect Sec Sys Ims
ESSLSH-24
4240-01-525-4777
Replacement Neck Strap
ESSM-2-6
5962-01-674-6520
Digital Microcircuit
ESSOG-B-026
5999-01-533-6206
Electronic Shielding Gasket
ESSOG-B-028
5999-01-533-5990
Electronic Shielding Gasket
ESSOG-B-128
5999-01-533-6159
Electronic Shielding Gasket
ESSOG-B-224-F
5999-01-561-5769
Electronic Shielding Gasket
ESSPN925
7530-00-989-0698
File Guide Card Set