1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-249-5285

5925-01-249-5285

Find complete technical information, availability, and procurement data for: 5925-01-249-5285

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-249-5285 to receive an up to date pricing and availability quote by email.

5925-01-249-5285
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-249-5285
Item Name Code
00136
Assigment Date
02/12/1987 (39 years ago)

0.040 inches minimum and 0.055 inches maximum bushing length, 0.469 inches minimum and 0.531 inches maximum center to center distance between terminals parallel to length, single pole type body style, 0.719 inches minimum and 0.781 inches maximum body length, 0.531 inches minimum and 0.593 inches maximum body width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Bushing Length
0.040 inches minimum and 0.055 inches maximum
Body Length
0.719 inches minimum and 0.781 inches maximum
Body Width
0.531 inches minimum and 0.593 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.469 inches minimum and 0.531 inches maximum
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
1.281 inches minimum and 1.343 inches maximum
Pole Quantity
1
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
2.5 amperes ac and 2.5 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac and 28.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2500.0 ac and 6000.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
thermal single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 push-pull
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.438 inches
Trip Delay Time In Seconds Per Rated Continuous Current
5.000 minimum at 200 pct and 20.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
general purpose
Trip Release Ambient Temp Rating
25.0 celsius nominal single location
Frequency In Hertz
400.0 single location
Thread Series Designator
uns
Terminal Type And Quantity
2 tab w/screw

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
2TC2-2-5 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-249-5285?
The FSCG of the NSN 5925-01-249-5285 is 5925
Does the NSN 5925-01-249-5285 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-249-5285 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-249-5285 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-249-5285 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-249-5285 was assigned to the Federal Catalog?
It was assigned 39 years ago, on Thu, Feb 12, 1987

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

26 58 48 19
6640-01-558-2938
Tissu Paraffin Processing Module
26-58-5091
5935-01-349-0066
Electrical Receptacle Connector
26-58036062
6620-01-360-9675
Dial Indicating Pressure Gage
26.5818
6625-01-053-4260
Special Scale Meter
26-58203
5330-01-301-4975
Plain Seal
26-5824
6625-01-121-9593
Ohmmeter
26.5833
6625-01-154-4263
Multiple Scale Meter
26-5846NO3
5940-01-422-6384
Terminal Board Shield
26-58701
2910-01-612-8092
Cam Actuated Fuel Pump
26.5885
6625-00-459-3217
Arbitrary Scale Meter
26-589-01
5935-01-612-5460
Indicator Adapter
26-589B
5820-00-392-9654
Silencing Pad
26-59-6051
5935-01-361-7135
Electrical Receptacle Connector
26-590
6515-00-332-6200
Hemostatic Clip Forceps
26.5903
6625-00-948-7372
Arbitrary Scale Meter