5925-01-239-2041

Find complete technical information, availability, and procurement data for: 5925-01-239-2041

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-239-2041 to receive an up to date pricing and availability quote by email.

5925-01-239-2041
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-239-2041
Item Name Code
00136
Assigment Date
08/26/1986 (39 years ago)

2.609 inches nominal body height, 1.032 inches nominal body width, 5.844 inches nominal body length, single pole type body style, 0.164 inches nominal mounting slot width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Mounting Slot Width
0.164 inches nominal
Body Length
5.844 inches nominal
Body Width
1.032 inches nominal
Body Height
2.609 inches nominal
Center To Center Distance Between Terminals Parallel To Length
3.546 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.750 inches nominal
Fragility Factor
moderately rugged
End Item Identification
6230-01-170-1408
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
2 threaded hole and 2 slot
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac single location
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic-hydraulic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
25.000 minimum at 200 pct and 150.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
Unpackaged Unit Weight
9.000 ounces nominal
Frequency In Hertz
50.0 or 60.0 single location
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
2 screw

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
016367-1 Circuit Breaker
845001A0062-1 Circuit Breaker
CE1-G3-U-15-120/240-1 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-239-2041?
The FSCG of the NSN 5925-01-239-2041 is 5925
Does the NSN 5925-01-239-2041 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-239-2041 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-239-2041 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-239-2041 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-239-2041 was assigned to the Federal Catalog?
It was assigned 39 years ago, on Tue, Aug 26, 1986

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

851-36899-051
5930-01-349-7540
Push Switch
851-36899-054
5930-01-349-0994
Push Switch
851-36899-057
5930-01-349-0997
Push Switch
851-36899-065
5930-01-349-7537
Push Switch
851-36899-066
5930-01-350-3705
Push Switch
851-36899-067
5930-01-349-7538
Push Switch
851-36899-074
6220-01-349-7541
Indicator Light
851-36899-075
6220-01-349-7542
Indicator Light
851-36899-077
6220-01-349-7534
Indicator Light
851-36899-078
6220-01-349-7535
Indicator Light
851-36899-079
5930-01-349-7543
Push Switch
851-36899-080
5930-01-349-0998
Push Switch
851-36899-082
5930-01-349-0999
Push Switch
851-36899-083
5930-01-349-7529
Push Switch
851-36899-084
5930-01-350-6426
Switch Assembly