1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-231-8241

5925-01-231-8241

Find complete technical information, availability, and procurement data for: 5925-01-231-8241

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-231-8241 to receive an up to date pricing and availability quote by email.

5925-01-231-8241
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-231-8241
Item Name Code
00136
Assigment Date
05/04/1986 (40 years ago)

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes:contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.

0.875 inches nominal center to center distance between terminals parallel to length, single pole type body style, 1.500 inches maximum body length, 0.625 inches maximum body width, 0.380 inches maximum bushing length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Bushing Length
0.380 inches maximum
Body Length
1.500 inches maximum
Body Width
0.625 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.875 inches nominal
End Item Identification
communications terminal,satellite an/tsc 94a(v)
Mounting Surface To Terminal End Distance
1.750 inches maximum
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
7.5 amperes ac single location
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.375 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.200 minimum at 200 pct and 1.700 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
hermetically sealed
Frequency In Hertz
50.0 or 60.0 single location
Thread Series Designator
unef
Terminal Type And Quantity
2 tab w/screw

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
AP6-9739-12 Circuit Breaker
SM-A-988733-12 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-231-8241?
The FSCG of the NSN 5925-01-231-8241 is 5925
Does the NSN 5925-01-231-8241 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-231-8241 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-231-8241 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-231-8241 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-231-8241 was assigned to the Federal Catalog?
It was assigned 40 years ago, on Sun, May 4, 1986

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

QH7437-102
5895-01-616-1986
Multiplexer
QH7816-102
5985-01-667-5697
Directional Coupler
QH8318-102
5915-01-620-0061
Hybrid Circuit Network
QH8D
5120-01-625-6129
Torque Wrench Adapter
QH902134A
5895-00-458-9107
Frequency Mixer Stage
QH902134B
6625-00-762-2369
Radio Frequency Power Divider
QH9044-102
5985-01-722-1617
Directional Coupler
QH9056
5985-01-680-8903
Directional Coupler
QH9972-10
5895-01-680-9650
Radio Frequency Power Divider
QHB-424B
5962-01-236-7839
Linear Microcircuit
QHB120
5925-00-513-2533
Circuit Breaker
QHB2-30
5985-00-991-1013
Transmission Line Coupler
QHB220
5925-00-523-9158
Circuit Breaker
QHB225
5925-00-513-2535
Circuit Breaker
QHC
5930-00-234-8622
Rotary Switch