5925-01-231-8134

Find complete technical information, availability, and procurement data for: 5925-01-231-8134

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-231-8134 to receive an up to date pricing and availability quote by email.

5925-01-231-8134
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-231-8134
Item Name Code
00136
Assigment Date
05/04/1986 (40 years ago)

A switch which is externally actuated by a lever and whose contacts open and close with an instantaneous (snap) action; includes items having one or more momentary positions. Includes switches (snap action) which use mercury to bridge contacts, and assemblages of complete switches (snap action) having common actuators. Excludes:switch,lever; switch,rotary; switch,knife; switch,sensitive; and switch,box.

1.380 inches nominal body length, 0.500 inches nominal bushing length, single pole type body style, 0.840 inches nominal center to center distance between terminals parallel to length, 0.560 inches nominal body width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Bushing Length
0.500 inches nominal
Body Length
1.380 inches nominal
Body Width
0.560 inches nominal
Center To Center Distance Between Terminals Parallel To Length
0.840 inches nominal
Mounting Surface To Terminal End Distance
1.630 inches nominal
Pole Quantity
1
Mounting Facility Type And Quantity
1 threaded bushing
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
25.0 amperes ac and 25.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac and 50.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac and 1000.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
thermal single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 push button
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.438 inches
Trip Delay Time In Seconds Per Rated Continuous Current
4.000 minimum at 200 pct and 15.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
fungus resistant
Trip Release Ambient Temp Rating
77.0 fahrenheit nominal single location
Frequency In Hertz
60.0 single location
Material
plastic case
Thread Series Designator
unef
Terminal Type And Quantity
2 clip

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
1610-068-250 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-231-8134?
The FSCG of the NSN 5925-01-231-8134 is 5925
Does the NSN 5925-01-231-8134 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-231-8134 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-231-8134 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-231-8134 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-231-8134 was assigned to the Federal Catalog?
It was assigned 40 years ago, on Sun, May 4, 1986

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

LD111-0020-0705
5306-01-296-6658
Shear Bolt
LD111-0020-0712
5306-01-658-8992
Shear Bolt
LD111-0020-0713
5306-01-645-7302
Shear Bolt
LD111-0020-0714
5306-01-658-8370
Shear Bolt
LD111-0020-1008
5306-01-265-8226
Shear Bolt
LD111-0020-1052
5306-01-260-0424
Shear Bolt
LD111-0020-1060
5306-01-267-0041
Shear Bolt
LD111-0020 THRU LD111-0025
5306-01-691-6935
Shear Bolt
LD111-0020A1008
5306-01-341-8910
Shear Bolt
LD111-0020A1074
5306-01-381-3781
Shear Bolt
LD111-0021-0305
5306-01-173-1067
Shear Bolt
LD111-0021-0306
5306-01-180-9103
Shear Bolt
LD111-0021-0307
5306-01-194-0606
Shear Bolt
LD111-0021-0312
5306-01-218-7123
Shear Bolt
LD111-0021-0317
5306-01-178-3693
Shear Bolt