Find complete technical information, availability, and procurement data for: 5925-01-207-6757

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-207-6757 to receive an up to date pricing and availability quote by email.

5925-01-207-6757
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-207-6757
Item Name Code
00136
Assigment Date
05/04/1985 (41 years ago)

1.928 inches minimum and 1.948 inches maximum center to center distance between terminals parallel to length, 2.052 inches minimum and 2.072 inches maximum distance between centerlines of mounting facilities parallel to body length, 0.740 inches minimum and 0.760 inches maximum body width, single pole type body style, 2.490 inches minimum and 2.510 inches maximum body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Body Length
2.490 inches minimum and 2.510 inches maximum
Body Width
0.740 inches minimum and 0.760 inches maximum
Center To Center Distance Between Terminals Parallel To Length
1.928 inches minimum and 1.948 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.052 inches minimum and 2.072 inches maximum
Fragility Factor
moderately rugged
Boss Height
0.130 inches minimum and 0.140 inches maximum
Mounting Surface To Terminal End Distance
2.611 inches nominal
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac single location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic-hydraulic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct and 20.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
dustproof and fungus proof
Frequency In Hertz
60.0 single location
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
2 threaded stud

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
AM1-A3-A-5 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-207-6757?
The FSCG of the NSN 5925-01-207-6757 is 5925
Does the NSN 5925-01-207-6757 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-207-6757 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-207-6757 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-207-6757 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-207-6757 was assigned to the Federal Catalog?
It was assigned 41 years ago, on Sat, May 4, 1985

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

031V3287000
5331-01-703-0365
O-Ring
031V4112000
5331-01-703-1971
O-Ring
031V4143000
5331-01-703-1232
O-Ring
031V4475000
5331-01-701-2728
O-Ring
031V4500000
5331-01-701-3064
O-Ring
031WA-291FGF-BMG
4820-01-568-5580
Butterfly Valve
031X4
9330-00-074-3249
Plastic Strip
032
4130-00-203-3321
Air Conditioning Filter Element
032-000
4940-01-204-7813
Blast Cleaning Machine
032-00004
5950-00-101-2359
Power Transformer
032-00008
5950-00-463-2579
Power Transformer
032-00009-0000
5945-01-514-8140
Reed Relay
032-0001-00
4130-00-454-9963
Valve Disk Retainer
032-00016
5950-00-239-2134
Power Transformer
032-0002-000
5935-01-450-8581
Electrical Conne Maintenance Kit