DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part 3179574-30 to receive an up to date pricing and availability quote by email.

3179574-30
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-198-9910
Item Name Code
00136
Assigment Date
01/17/1985 (41 years ago)

1.937 inches maximum body width, 0.380 inches maximum bushing length, +0.3503 to 0.3537 inches thread pitch diameters, 1.562 inches maximum body length, multipole-single actuator type body style

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Thread Pitch Diameters
+0.3503 to 0.3537 inches
Body Style
multipole-single actuator type
Bushing Length
0.380 inches maximum
Body Length
1.562 inches maximum
Body Width
1.937 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.844 inches minimum and 0.906 inches maximum
Center To Center Distance Between Terminals Parallel To Width
0.594 inches minimum and 0.656 inches maximum
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
1.828 inches maximum
Pole Quantity
2
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac and 20.0 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac and 50.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac and 1000.0 dc all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
between pole one and two
Internal Trip Release Configuration
series trip all locations
Nominal Thread Size
0.375 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.200 minimum at 200 pct and 6.000 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
hermetically sealed
Frequency In Hertz
400.0 all locations
Thread Series Designator
unef
Terminal Type And Quantity
4 wire hook

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
3179574-30 Circuit Breaker
AP12-1R-3062-30 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-198-9910?
The FSCG of the NSN 5925-01-198-9910 is 5925
Does the NSN 5925-01-198-9910 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-198-9910 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-198-9910 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-198-9910 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-198-9910 was assigned to the Federal Catalog?
It was assigned 41 years ago, on Thu, Jan 17, 1985

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

296050006
9905-01-585-4599
Marker Tag
296050007
5925-01-609-6199
Circuit Breaker Locking Device
296050008
5925-01-609-6121
Circuit Breaker Locking Device
296050009
5925-01-609-6208
Circuit Breaker Detent
296050018
5925-01-609-6211
Circuit Breaker Locking Device
296050020-1
5935-01-609-6893
Circuit Breaker Adapter Kit
296050020-2
5935-01-609-6266
Circuit Breaker Adapter Kit
296050024
5925-01-631-0847
Circuit Breaker Locking Device
296050029-248
5925-01-688-0042
Circuit Breaker Locking Device
296050029-266
5925-01-688-0033
Circuit Breaker Locking Device
296050029-2825
5925-01-688-0029
Circuit Breaker Locking Device
296050029-802
5925-01-688-0037
Circuit Breaker Locking Device
29605004
5985-01-583-1235
Antenna Control
29605006
5895-01-583-0315
Receiver Group
29605007
5930-01-584-8657
Switch Assembly